Fluke 53 II Digital Digital Thermometer, Type R, Type J, Type E, Type N, K, Type T, Type S Probe, 1 Input(s), 1767 °C
- RS庫存編號:
- 736-1507
- Distrelec 貨號:
- 176-66-451
- 製造零件編號:
- 3621096
- 製造商:
- Fluke
此圖片僅供參考,請參閲產品詳細資訊及規格
小計(1 件)*
TWD29,532.00
(不含稅)
TWD31,008.60
(含稅)
訂單超過 $1,300.00 免費送貨
製造商存貨
- 準備從 2026年6月24日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD29,532.00 |
* 參考價格
- RS庫存編號:
- 736-1507
- Distrelec 貨號:
- 176-66-451
- 製造零件編號:
- 3621096
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Digital Thermometer | |
| Maximum Temperature Measurement | 1767°C | |
| Model Number | 53 II | |
| Thermometer Type | Digital | |
| Probe Type | Type R, Type J, Type E, Type N, K, Type T, Type S | |
| Accuracy | ± 0.05 % + 0.3 °C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Battery Life | 1000h | |
| Hazardous Area Certification | NO | |
| Weight | 400g | |
| Length | 173mm | |
| Height | 38mm | |
| Width | 86mm | |
| Standards/Approvals | CE, CSA, TUV | |
| Temperature Scale | Fahrenheit, Centigrade | |
| Minimum/Maximum Recordings | Yes | |
| Battery Type | AA | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Digital Thermometer | ||
Maximum Temperature Measurement 1767°C | ||
Model Number 53 II | ||
Thermometer Type Digital | ||
Probe Type Type R, Type J, Type E, Type N, K, Type T, Type S | ||
Accuracy ± 0.05 % + 0.3 °C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Battery Life 1000h | ||
Hazardous Area Certification NO | ||
Weight 400g | ||
Length 173mm | ||
Height 38mm | ||
Width 86mm | ||
Standards/Approvals CE, CSA, TUV | ||
Temperature Scale Fahrenheit, Centigrade | ||
Minimum/Maximum Recordings Yes | ||
Battery Type AA | ||
豁免
Fluke Digital Thermometer, 1767°C Maximum Temperature Measurement, 0.05% + 0.3°C Accuracy - 3621096
This digital thermometer is a single-input, battery-powered handheld instrument designed for logging and spot measurement of contact temperatures across industrial, laboratory and HVAC environments. It accepts a wide range of thermocouple types and displays readings on a large backlit screen, while internal memory captures temperature events for later review.
Features & Benefits
• 0.05% accuracy Plus 0.3°C ensures precise measurements for calibration tasks
• Logs up to 500 readings at user-set intervals for trend analysis
• Accepts J, K, T, E, N, R and S thermocouples to cover diverse sensors
• Internal real-time clock time-stamps each recorded event for traceability
• Infrared USB export enables downstream analysis with PC software
• Sleep mode and AA power deliver around 1000 h operation on three batteries
• Logs up to 500 readings at user-set intervals for trend analysis
• Accepts J, K, T, E, N, R and S thermocouples to cover diverse sensors
• Internal real-time clock time-stamps each recorded event for traceability
• Infrared USB export enables downstream analysis with PC software
• Sleep mode and AA power deliver around 1000 h operation on three batteries
**Applications**
• Suitable for process calibration in manufacturing plants
• Ideal for HVAC commissioning and maintenance checks
• Used for food-safety temperature verification and records
• Can be used for motor and bearing contact temperature checks
• Suitable for lab and QA temperature logging during tests
• Ideal for HVAC commissioning and maintenance checks
• Used for food-safety temperature verification and records
• Can be used for motor and bearing contact temperature checks
• Suitable for lab and QA temperature logging during tests
Which thermocouple types can I connect for high-temperature work?
It supports J, K, T, E, N and the PLATINUM types R and S, with R and S capable of measuring up to 1767°C.
How is logged data reviewed and exported?
Logged entries can be recalled on the instrument and exported via an infrared USB link for use with compatible PC software.
What battery arrangement and access does it use?
It runs from three standard AA batteries and features an easy-access battery door that permits replacement without breaking the calibration seal.
How does the instrument handle accuracy compensation?
An electronic offset function compensates for thermocouple errors to optimise overall measurement accuracy.
What environmental limits apply during operation?
It is designed to operate between -10°C and 50°C with specified humidity limits to avoid condensation.
Note
Fluke 53-2B & 54-2B need the Fluke FVF- SC2 FlukeView software and USB lead RS 385-0599
Supplied with
Instruction leaflet, holster, battery (fitted)
1 off type K thermocouple (Model 51-II & model 53-2-B)
2 off type K thermocouple (Model 52-II & Model 54-2-B)
1 off type K thermocouple (Model 51-II & model 53-2-B)
2 off type K thermocouple (Model 52-II & Model 54-2-B)
相關連結
- Fluke 54 II B Wired Digital Thermometer K Type J Type S 2 Input(s), 1767 °C
- Fluke 52 II Wired Digital Thermometer K Type E Probe 1767 °C Max, ±0.05 % + 0.3°C
- RS PRO 1315 Wired Digital Thermometer Type T K Type S 1 Input(s)
- RS PRO 1314 Wired Digital Thermometer K Type S Type R 2 Input(s)
- RS PRO 1313 Wired Digital Thermometer Type R Type J K 1 Input(s)
- Fluke 51 II Wired Digital Thermometer K Type E Probe 1372 °C Max, ±0.3 K Accuracy
- Sefram SEFRAM9816B Desk Digital Thermometer K Type N Type T 4 Input(s), 1767
- Chauvin Arnoux CA 1822 Wired Digital Thermometer Type R Type S Type T 2 Input(s),