Alpha Wire XTRA-GUARD 2 Control Cable, 3 Cores, 0.56mm² 20 AWG, Screened, 30 m, Black PVC Sheath

小計(1 卷,共 30 米)*

TWD13,320.00

(不含稅)

TWD13,986.00

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 126 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷
每卷
每米*
1 +TWD13,320.00TWD444.00

* 參考價格

RS庫存編號:
409-242
製造零件編號:
25463 BK005
製造商:
Alpha Wire
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Alpha Wire

Product Type

Control Cable

Series

XTRA-GUARD 2

Number of Cores

3

Conductor Material

Tin Copper Wire

Jacket Material

PVC

Jacket Colour

Black

Armoured

Yes

Screened/Unscreened

Screened

Cable Length

30m

Outside Diameter

5.66mm

Voltage

300V

Minimum Operating Temperature

-30°C

Standards/Approvals

CSA, UL, CE

Maximum Operating Temperature

90°C

Hazardous Area Certification

No

Cable CSA

0.56mm²

Fire Behaviour

Flame Retardant to IEC 60332-1-2, Low Smoke Zero Halogen (LSZH), CPR, Flame resistance to UL1581 VW-1 and IEC60332-1

American Wire Gauge

20AWG

Size of Strands

320μm

Core Strands

7 x 320 μm

Number of Strands

7

Belden XTRA-GUARD 2 Series Control Cable, 30m Cable Length, 3 Cores - 25463 BK005


This control cable is a screened, three-core product designed for industrial signalling and control in automation and electrical systems. It is intended for installations requiring a robust, flame-retardant conductor assembly with reduced halogen emissions and a Durable outer sheath suitable for varied ambient conditions.

Features & Benefits


• Tin-plated copper conductors reduce corrosion and improve conductivity
• Screened construction limits electromagnetic interference for accurate signals
• Rated 300V to support common low-voltage control circuits
• Operating temperature range -30°C to 90°C for broad environmental use
• Low smoke zero halogen jacket limits toxic emissions in confined spaces
• VW-1/IEC flame resistance improves safety during fire exposure

**Applications**


• Suitable for factory automation control panels and motor controllers
• Ideal for wiring machine tools and conveyor control systems
• Used with distributed I/O and PLC field connections
• Can be used for robotics signal and sensor cabling in plants
• Suitable for indoor cable runs where reduced smoke is required

What conductor construction is used to meet flexibility needs?


Each core comprises multiple fine strands of tin-plated copper configured as 20 AWG (7/28) to balance flexibility with electrical performance.

How is the screening implemented and what benefit does it give?


An aluminium/Mylar foil with a tinned-copper drain wire provides overall screening to reduce external electromagnetic disturbance and simplify termination to earth.

What materials form the insulation and outer sheath?


Individual cores are insulated with nominal PVC and the outer jacket is a polyurethane-specified construction that provides mechanical protection and sunlight resistance.

How does the cable behave electrically for system design?


Nominal capacitance and inductance values are provided for engineering calculations, and conductor DCR and overall shield DCR allow accurate resistance estimates for lengths.

What handling limits should be observed during installation?


Follow a minimum bend radius of 10x cable diameter and keep pull tension below the specified maximum to avoid mechanical damage.