Alpha Wire XTRA-GUARD 2 Control Cable, 3 Cores, 0.56mm² 20 AWG, Screened, 30 m, Black PVC Sheath
- RS庫存編號:
- 409-242
- 製造零件編號:
- 25463 BK005
- 製造商:
- Alpha Wire
小計(1 卷,共 30 米)*
TWD13,320.00
(不含稅)
TWD13,986.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 126 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷 | 每卷 | 每米* |
|---|---|---|
| 1 + | TWD13,320.00 | TWD444.00 |
* 參考價格
- RS庫存編號:
- 409-242
- 製造零件編號:
- 25463 BK005
- 製造商:
- Alpha Wire
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Alpha Wire | |
| Product Type | Control Cable | |
| Series | XTRA-GUARD 2 | |
| Number of Cores | 3 | |
| Conductor Material | Tin Copper Wire | |
| Jacket Material | PVC | |
| Jacket Colour | Black | |
| Armoured | Yes | |
| Screened/Unscreened | Screened | |
| Cable Length | 30m | |
| Outside Diameter | 5.66mm | |
| Voltage | 300V | |
| Minimum Operating Temperature | -30°C | |
| Standards/Approvals | CSA, UL, CE | |
| Maximum Operating Temperature | 90°C | |
| Hazardous Area Certification | No | |
| Cable CSA | 0.56mm² | |
| Fire Behaviour | Flame Retardant to IEC 60332-1-2, Low Smoke Zero Halogen (LSZH), CPR, Flame resistance to UL1581 VW-1 and IEC60332-1 | |
| American Wire Gauge | 20AWG | |
| Size of Strands | 320μm | |
| Core Strands | 7 x 320 μm | |
| Number of Strands | 7 | |
| 選取全部 | ||
|---|---|---|
品牌 Alpha Wire | ||
Product Type Control Cable | ||
Series XTRA-GUARD 2 | ||
Number of Cores 3 | ||
Conductor Material Tin Copper Wire | ||
Jacket Material PVC | ||
Jacket Colour Black | ||
Armoured Yes | ||
Screened/Unscreened Screened | ||
Cable Length 30m | ||
Outside Diameter 5.66mm | ||
Voltage 300V | ||
Minimum Operating Temperature -30°C | ||
Standards/Approvals CSA, UL, CE | ||
Maximum Operating Temperature 90°C | ||
Hazardous Area Certification No | ||
Cable CSA 0.56mm² | ||
Fire Behaviour Flame Retardant to IEC 60332-1-2, Low Smoke Zero Halogen (LSZH), CPR, Flame resistance to UL1581 VW-1 and IEC60332-1 | ||
American Wire Gauge 20AWG | ||
Size of Strands 320μm | ||
Core Strands 7 x 320 μm | ||
Number of Strands 7 | ||
Belden XTRA-GUARD 2 Series Control Cable, 30m Cable Length, 3 Cores - 25463 BK005
This control cable is a screened, three-core product designed for industrial signalling and control in automation and electrical systems. It is intended for installations requiring a robust, flame-retardant conductor assembly with reduced halogen emissions and a Durable outer sheath suitable for varied ambient conditions.
Features & Benefits
• Tin-plated copper conductors reduce corrosion and improve conductivity
• Screened construction limits electromagnetic interference for accurate signals
• Rated 300V to support common low-voltage control circuits
• Operating temperature range -30°C to 90°C for broad environmental use
• Low smoke zero halogen jacket limits toxic emissions in confined spaces
• VW-1/IEC flame resistance improves safety during fire exposure
• Screened construction limits electromagnetic interference for accurate signals
• Rated 300V to support common low-voltage control circuits
• Operating temperature range -30°C to 90°C for broad environmental use
• Low smoke zero halogen jacket limits toxic emissions in confined spaces
• VW-1/IEC flame resistance improves safety during fire exposure
**Applications**
• Suitable for factory automation control panels and motor controllers
• Ideal for wiring machine tools and conveyor control systems
• Used with distributed I/O and PLC field connections
• Can be used for robotics signal and sensor cabling in plants
• Suitable for indoor cable runs where reduced smoke is required
• Ideal for wiring machine tools and conveyor control systems
• Used with distributed I/O and PLC field connections
• Can be used for robotics signal and sensor cabling in plants
• Suitable for indoor cable runs where reduced smoke is required
What conductor construction is used to meet flexibility needs?
Each core comprises multiple fine strands of tin-plated copper configured as 20 AWG (7/28) to balance flexibility with electrical performance.
How is the screening implemented and what benefit does it give?
An aluminium/Mylar foil with a tinned-copper drain wire provides overall screening to reduce external electromagnetic disturbance and simplify termination to earth.
What materials form the insulation and outer sheath?
Individual cores are insulated with nominal PVC and the outer jacket is a polyurethane-specified construction that provides mechanical protection and sunlight resistance.
How does the cable behave electrically for system design?
Nominal capacitance and inductance values are provided for engineering calculations, and conductor DCR and overall shield DCR allow accurate resistance estimates for lengths.
What handling limits should be observed during installation?
Follow a minimum bend radius of 10x cable diameter and keep pull tension below the specified maximum to avoid mechanical damage.
相關連結
- Alpha Wire XTRA-GUARD 2 Control Cable 0.56mm² 20 AWG 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire XTRA-GUARD 2 Control Cable 0.56mm² 20 AWG 30 m, Black Polyvinyl Chloride Sheath
- Alpha Wire Xtra-Guard 4 Performance Cable Control Cable 0.56mm² 20 AWG 30 m, Black Thermoplastic
- Alpha Wire Xtra-Guard 4 Performance Cable Control Cable 0.56mm² 20 AWG 30 m, Black Thermoplastic
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56mm² 20 AWG 30 m, Black Polyvinyl
- Alpha Wire Xtra-Guard 4 Performance Cable Control Cable 0.56mm² 20 AWG 30 m, Black Thermoplastic
- Alpha Wire Xtra-Guard 4 Performance Cable Control Cable 0.56mm² 20 AWG 30 m, Black Thermoplastic
- Alpha Wire Xtra-Guard 2 Performance Cable Control Cable 0.56mm² 20 AWG 30 m, Black Polyvinyl