Alpha Wire, 0.56mm², Screened Polyvinyl Chloride Sheath

小計(1 卷,共 30 米)*

TWD11,250.00

(不含稅)

TWD11,812.50

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 26 件從 2026年3月23日 起發貨
  • 加上 4 件從 2026年3月24日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
每卷
每米*
1 +TWD11,250.00TWD375.00

* 參考價格

RS庫存編號:
409-224
製造零件編號:
25464 BK005
製造商:
Alpha Wire
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Alpha Wire

Jacket Material

Polyvinyl Chloride

Armoured

Yes

Screened/Unscreened

Screened

Core Strands

7

Belden XTRA-GUARD 2 Series Control Cable, 30m Cable Length, 4 Cores - 25464 BK005


This control cable is designed for signal and control circuits in industrial automation and electrical installations where screened conductors and reduced emission of combustion products are required. It combines multi-core screening and tinned copper conductors to provide stable connectivity and suitability for installations with elevated ambient temperatures.

Features & Benefits


• Screened construction reduces electromagnetic interference for cleaner signals
• Tin-plated copper conductors resist corrosion for extended service life
• Fire-resistant insulation meets IEC 60332-1 for safer fault conditions
• Low smoke zero halogen sheath limits toxic emissions during combustion
• Rated for 300V enabling compatibility with common control systems
• Maximum operating temperature of 90 °C supports high-temperature environments

Applications


• Suitable for factory automation control cabinets and racks
• Used for motor starter and relay circuits in machinery
• Ideal for wiring between PLCs and field instrumentation
• Can be used for cable runs in transportation and building services
• Used with screened inputs where low emission of smoke is necessary

What conductor construction is used and why does it matter?


Each core consists of multi-stranded tin-plated copper conductors which improve flexibility for routing and offer enhanced resistance to corrosion compared with bare copper.

How is screening implemented and how does it affect installation?


The assembly uses an aluminium/Mylar tape with a tinned copper drain conductor to provide a continuous return path for interference and to simplify termination to earth.

What sheath material is fitted and what are its mechanical traits?


The outer sheath is a PVC compound selected for abrasion and sunlight resistance while maintaining a flexible profile suitable for cable management.

What environmental temperature range can be expected in service?


The cable is specified for continuous operation between -30 °C and 90 °C to accommodate cold storage areas and warm plant-floor locations.

What electrical characteristics aid engineering selection?


Nominal capacitance and inductance values are provided for system calculations and the voltage rating is 300V for typical control networks.