ABB 1SBL41 Contactor, 48V Coil, 3-Pole, 100 A 48V, 4 NO/1 NC, 690V

小計(1 件)*

TWD43,465.00

(不含稅)

TWD45,638.25

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年11月10日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD43,465.00

* 參考價格

RS庫存編號:
253-2045
製造零件編號:
1SBL419025R8311
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Contactor

Coil Voltage

48V

Number of Poles

3

Contact Voltage

690V

Contact Current

100A

Series

1SBL41

Function

Control Unit

Normal State Configuration

4 NO/1 NC

Number of Auxiliary Contacts

2

Auxiliary Contact Configuration

1 NO/1 NC

Terminal Type

Screw

Minimum Operating Temperature

-40°C

Operational Current Ie

6A

Contactor Application

Control Unit

Control Circuit Voltage Uc

48V

Maximum Operating Temperature

70°C

Standards/Approvals

IEC 60947-4-1, IEC 60947-5-1, UL/CSA, VDE 0110

Width

94mm

Length

108mm

Depth

108mm

Pole and Throw Configuration

1P

COO (Country of Origin):
BG

ABB 1SBL41 Series Contactor, 125A Contact Current, 48V Coil Voltage - 1SBL419025R8311


This contactor is a DC switching device designed for control applications in industrial electrical systems. It operates with a 48V control circuit and is intended to manage three-pole power paths, providing reliable switching of medium-voltage DC loads up to 690 V. The unit includes a mix of main and auxiliary contacts and is suited to panel- or cabinet-mounted installations where screw terminals are required.

Features and Benefits:


• 125 A continuous contact rating for heavy-duty current handling
• 3-pole configuration enabling simultaneous multi-phase DC switching
• 1 NO and 1 NC auxiliary contact for Basic control logic integration
• 48V Coil voltage for compatibility with common control supplies
• IEC 60947-4-1 compliant construction for recognised electrical behaviour
• Rated for operation between −40 °C and 70 °C for varied environments

Applications


• Suitable for battery bank isolation in DC storage systems
• Ideal for motor-drive disconnect in industrial automation panels
• Used for load switching in renewable energy converters
• Can be used for control and protection circuits in traction systems

What type of Terminal connections does it use for wiring?


Termination is via screw terminals, allowing secure clamping of conductor lugs and straightforward installation with standard tools.

How many auxiliary contacts are available for control circuits?


Two auxiliary contacts are provided, arranged as one normally open and one normally closed contact for straightforward signalling and interlocking.

What approvals indicate suitability for safety-conscious installations?


The device meets IEC standards and holds approvals from UL/CSA and VDE, reflecting adherence to recognised industrial specifications.

What is the operational current for the Coil control circuit?


The control circuitry is rated for an operational current of 6 A, matching typical control-loop requirements.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。