暫時無法供應
我們無法確定此產品何時有貨,RS 預計將其從我們的產品目錄中移除。
替代產品
該產品我們目前不提供。 這是我們推薦的替代產品。
個
TWD11,439.00
(不含稅)
TWD12,010.95
(含稅)
- RS庫存編號:
- 136-8699
- 製造零件編號:
- 5203BF1
- 製造商:
- PR Electronics
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | PR Electronics | |
| Product Type | Galvanic Barrier | |
| Number of Channels | 1 | |
| Barrier Type | Galvanic Barrier | |
| Mount Type | DIN Rail | |
| Hazardous Area Certification | IECEx, ATEX | |
| Terminal Type | Screw | |
| Supply Voltage | 21.6V ac, 253V ac, 19.2V ac, 300V ac | |
| IP Rating | IP20 | |
| Maximum Safety Current | 400mA | |
| Minimum Operating Temperature | -20°C | |
| Maximum Safety Voltage | 253V ac, 300V ac | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | 2014/35/EU, EAC TR-CU 020/2011, IEC 61140, 2014/30/EU | |
| Series | 5200 | |
| 選取全部 | ||
|---|---|---|
品牌 PR Electronics | ||
Product Type Galvanic Barrier | ||
Number of Channels 1 | ||
Barrier Type Galvanic Barrier | ||
Mount Type DIN Rail | ||
Hazardous Area Certification IECEx, ATEX | ||
Terminal Type Screw | ||
Supply Voltage 21.6V ac, 253V ac, 19.2V ac, 300V ac | ||
IP Rating IP20 | ||
Maximum Safety Current 400mA | ||
Minimum Operating Temperature -20°C | ||
Maximum Safety Voltage 253V ac, 300V ac | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals 2014/35/EU, EAC TR-CU 020/2011, IEC 61140, 2014/30/EU | ||
Series 5200 | ||
- COO (Country of Origin):
- DK
PR Electronics 5203B - Ex Solenoid/Alarm Driver
PR Electronics 5203B Universal Ex driver for solenoids, acoustic alarms and LEDs. Used anywhere intrinsically safe levels of energy need to be sent to devices located in a flammable atmosphere. The PR 5203B driver has a safety barrier function for the on/off control of solenoids, LEDs and alarms mounted in hazardous areas. The high level of electrical isolation means that input pulses sensed at the 5203B are not electrically connected to the output pulse.
Features and Benefits
• 3.75 kVac galvanic isolation between input, output and supply
• Digital input per channel for the control of the I.S. output voltage
• Front LED indicates operation status and malfunction
• DIN rail mounting
• Can be mounted in the safe area or in zone 2 / div. 2 and transmit signals to zone 0, 1, 2 and zone 20, 21, 22
• DIP-Switch programming
PR Electronics - Ex Interfaces
相關連結
- PR Electronics Galvanic Barrier IECEx
- PR Electronics Galvanic Barrier IECEx, ATEX
- PR Electronics 2 Channel Galvanic Barrier ATEX
- PR Electronics 2 Channel Galvanic Barrier ATEX, IECEx
- PR Electronics 2 Channel Galvanic Barrier IECEx, ATEX
- PR Electronics Galvanic Barrier, ATEX
- PR Electronics 2 Channel Galvanic Barrier, ATEX
- Turck Galvanic Barrier IECEx