Chauvin Arnoux CA 773 IP2X, Backlit LCD, LED Voltage tester, 1000 V ac, 1400V dc, Continuity Check, Battery Powered,
- RS庫存編號:
- 896-2183
- 製造零件編號:
- P01191773A
- 製造商:
- Chauvin Arnoux
小計(1 件)*
TWD8,943.00
(不含稅)
TWD9,390.15
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 39 件準備從其他地點送貨
- 加上 6 件從 2026年2月02日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD8,943.00 |
* 參考價格
- RS庫存編號:
- 896-2183
- 製造零件編號:
- P01191773A
- 製造商:
- Chauvin Arnoux
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Chauvin Arnoux | |
| Maximum Voltage | 1000 V ac, 1400V dc | |
| Continuity Check | Yes | |
| Safety Category | CAT IV 1000V | |
| Display Type | Backlit LCD, LED | |
| RCD Trip Test | Yes | |
| IP Rating | IP65 | |
| Battery Type | AA, LR6 | |
| Power Source | Battery | |
| Dimensions | 228 x 60 x 39mm | |
| Weight | 350g | |
| Height | 39mm | |
| Length | 228mm | |
| Maximum Operating Temperature | +45°C | |
| Width | 60mm | |
| Safety Category Voltage | 1000V | |
| Safety Category Level | CAT IV | |
| Minimum Operating Temperature | -15°C | |
| Model Number p | CA 773 IP2X | |
| 選取全部 | ||
|---|---|---|
品牌 Chauvin Arnoux | ||
Maximum Voltage 1000 V ac, 1400V dc | ||
Continuity Check Yes | ||
Safety Category CAT IV 1000V | ||
Display Type Backlit LCD, LED | ||
RCD Trip Test Yes | ||
IP Rating IP65 | ||
Battery Type AA, LR6 | ||
Power Source Battery | ||
Dimensions 228 x 60 x 39mm | ||
Weight 350g | ||
Height 39mm | ||
Length 228mm | ||
Maximum Operating Temperature +45°C | ||
Width 60mm | ||
Safety Category Voltage 1000V | ||
Safety Category Level CAT IV | ||
Minimum Operating Temperature -15°C | ||
Model Number p CA 773 IP2X | ||
豁免
- COO (Country of Origin):
- CN
C.A 773 IP2X Voltage Absence Tester (VAT) CAT IV 1000V
The C.A 773 IP2X Voltage Tester is a VAT with digital display and LEDs for voltages up to 1000 VAC/1400 VDC with with audible extended continuity and phase rotation testing. The Voltage Tester also offers trip testing of RCDs rated 30 mA (or less), as well as lighting of the test probe/point of measurement and digital display of the resistance and voltage.
1000 VAC / 1400 VDC
Single-pole phase test
Continuity andresistance test with audible and visual indication
Two-pole phase sequence test with 2-wire method
RCD trip testing and Detection of stray voltages
Lighting of point of measurement. CAT IV 1000V
IP65
Single-pole phase test
Continuity andresistance test with audible and visual indication
Two-pole phase sequence test with 2-wire method
RCD trip testing and Detection of stray voltages
Lighting of point of measurement. CAT IV 1000V
IP65
Standards
IEC 61243-3:2009, EN 61243-3:2010, IEC 61010 1,000 V CAT IV
Supplied with
Voltage absence tester, User's guide in 5 languages, 2 x 1.5 V LR03/AAA batteries, 1 set of IP2X removable test probes Ø 4 mm and 1 Velcro strap.
相關連結
- Chauvin Arnoux CA 773 1000 V ac Continuity Check CAT IV
- Chauvin Arnoux CA 771 IP2X 1000 V ac Continuity Check CAT IV
- Chauvin Arnoux CA 771 1000 V ac Continuity Check CAT IV
- Chauvin Arnoux CA 762 IP2X 690 V ac Continuity Check CAT IV
- Chauvin Arnoux CA 742 IP2X 690 V ac Continuity Check CAT IV
- Chauvin Arnoux CA 745N 690V ac/dc Battery Powered, CAT III 600V
- Chauvin Arnoux TX 01 690V ac/dc Battery Powered, CAT III 600V
- Chauvin Arnoux CA 762 690 V ac Continuity Check CAT IV
