SICK Pressure Switch -1 bar to 0 bar
- RS庫存編號:
- 213-3301
- 製造零件編號:
- PAC50-ACA / 1062951
- 製造商:
- SICK
小計(1 件)*
TWD6,507.00
(不含稅)
TWD6,832.35
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 8 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD6,507.00 |
* 參考價格
- RS庫存編號:
- 213-3301
- 製造零件編號:
- PAC50-ACA / 1062951
- 製造商:
- SICK
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | SICK | |
| Product Type | Pressure Switch | |
| Port Size | 4 mm | |
| Minimum Operating Pressure | -1bar | |
| Current | 40mA | |
| Switch Output | Push Pull, NPN, 2 x PNP | |
| Suitable Medias | Air, Gas | |
| Mount Type | DIN Rail | |
| Pressure Type | Gauge Pressure | |
| Voltage | 30V dc | |
| Analogue Output | 0 to 10 V dc, 4 to 20 mA | |
| Series | PAC50-ACA | |
| Maximum Operating Pressure | 0 bar | |
| Minimum Operating Temperature | 0°C | |
| Port Gender | Female | |
| Connection Thread Standard | DIN ISO 16030 | |
| Maximum Operating Temperature | 60°C | |
| Height | 63mm | |
| Width | 35mm | |
| Standards/Approvals | EMC Directive:2004/108/EC, EN 61326-2-3 | |
| Depth | 35mm | |
| Hazardous Area Certification | NO | |
| IP Rating | IP65, IP67 | |
| LED Indicator | Yes | |
| 選取全部 | ||
|---|---|---|
品牌 SICK | ||
Product Type Pressure Switch | ||
Port Size 4 mm | ||
Minimum Operating Pressure -1bar | ||
Current 40mA | ||
Switch Output Push Pull, NPN, 2 x PNP | ||
Suitable Medias Air, Gas | ||
Mount Type DIN Rail | ||
Pressure Type Gauge Pressure | ||
Voltage 30V dc | ||
Analogue Output 0 to 10 V dc, 4 to 20 mA | ||
Series PAC50-ACA | ||
Maximum Operating Pressure 0 bar | ||
Minimum Operating Temperature 0°C | ||
Port Gender Female | ||
Connection Thread Standard DIN ISO 16030 | ||
Maximum Operating Temperature 60°C | ||
Height 63mm | ||
Width 35mm | ||
Standards/Approvals EMC Directive:2004/108/EC, EN 61326-2-3 | ||
Depth 35mm | ||
Hazardous Area Certification NO | ||
IP Rating IP65, IP67 | ||
LED Indicator Yes | ||
- COO (Country of Origin):
- TH
Overview
At a glance
Large display shows system pressure, output states, and switching points
Three large function keys, intuitive menu navigation
Measuring range for gauge pressure (vacuum and overpressure)
Two independently programmable switching outputs, optional analog output
Installation on mounting rail, wall or switch panel
Variant for leakage monitoring
IO-Link
Your Benefit
Bi-color display (green/red) clearly shows the status of the output signal (within or outside the target range)
Quick overview of important system parameters due to advanced display functions
Intuitive operation allows simple and quick commissioning
Pressure connections on the back and bottom and configurable output signals for a high level of installation flexibility
High reliability thanks to the rugged design (IP65 and IP67 enclosure rating) and proven technology
Less variants for different requirements and lower inventory costs
Convenient, cost-effective solution for leakage measurement
Measurement of pneumatic pressure of a food slicer
Monitoring and definition of the pressure in the vacuum gripper
For improved monitoring of air pressure, the PAC50 electronic pressure switch from SICK offers more at a glance – the large bi-color display allows you to identify from a distance if the pressure falls within the target range. Three large function keys and intuitive menu navigation make operating the PAC50 easy.
What makes the PAC50 so special? It offers up to two digital switching outputs and an optional analog output in just one device. The output signals can be easily adjusted to the available control system. Thanks to the optional IO-Link, the controller or PLC can quickly and accurately pass the device parameters to the sensor when changing the format or replacing the sensor, which significantly reduces downtime. The PAC50 is ideal for use in industrial environments due to its waterproof housing with an IP 65/IP 67 enclosure rating.
Applications
Compressed-air monitoring and measurement in machines and systems
Pressure measurement in air and in dry, non-corrosive gases
Pressure measurement on compressed-air maintenance units
Vacuum monitoring in handling and robotics applications
Leakage monitoring in closed compressed air systems
Compressed-air monitoring for the robot gripper
Measurement of pneumatic pressure on a meat slicer
Perfect deep drawing of product trays
Monitoring of the pneumatic pressure
Monitoring of the pneumatic pressure
Integrated measurement of pressure and flow in the service unit
Fixing the wooden strip
Pressure monitoring on vacuum gripper
Monitoring the vacuum at the suction table
Pressure monitoring in the spraying unit
Pressure monitoring in the vacuum removal gripper
Monitoring of the vacuum pressure using the PAC50
Improved energy management in compressed air systems
Pressure monitoring in the handling device
Pressure monitoring in the handling device
相關連結
- SICK Pressure Switch -1 bar to 0 bar
- SICK Pressure Switch 0 bar to 10 bar
- SICK Pressure Switch 0 bar to 6 bar
- SICK Pressure Switch -1 bar to 1 bar
- SICK Pressure Switch -1 bar to 10 bar
- SICK PAC50 Series Pressure Sensor Pressure Switch Gauge Reading
- SICK PAC50 Series Pressure Sensor Pressure Switch Gauge Reading
- SICK PAC50 Series Pressure Sensor Pressure Switch Gauge Reading