Festo Vacuum Pump, 0.95 mm nozzle, 4.5 bar 25 L/min, VN series

小計(1 件)*

TWD1,619.00

(不含稅)

TWD1,699.95

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 19 件從 2026年7月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD1,619.00

* 參考價格

RS庫存編號:
202-2427
Distrelec 貨號:
301-69-876
製造零件編號:
VN-10-H-T3-PI4-VI4-RI4
製造商:
Festo
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Festo

Product Type

Vacuum Pump

Maximum Suction Flow

25L/min

Maximum Vacuum Pressure

4.5bar

Nozzle Diameter

0.95mm

Series

VN

Silencer

No

Inlet Thread Standard

G 1/8

Outlet Thread Standard

G 1/8

Maximum Operating Temperature

60°C

Standards/Approvals

ISO8573-1:2010 (7:4:4), RoHS

Hazardous Area Certification

No

Outlet Port Size

1/8 in G

COO (Country of Origin):
HU

Festo Series VN Vacuum Pump, 25L/min Maximum Suction Flow, 4.5 Bar Maximum Vacuum Pressure - VN-10-H-T3-PI4-VI4-RI4, Numeric Part Number: 193500


This vacuum pump provides compact, pneumatic suction for automation and industrial tasks. It is designed to draw modest volumes of Air for component handling and process support within equipment that requires a small, robust vacuum source. The unit operates within standard industrial temperature limits and connects using G 1/8 ports for straightforward integration into pneumatic systems.

Features and Benefits:


• 25L/min maximum suction flow supports light-duty pick-and-place
• 4.5bar maximum vacuum pressure enables secure part holding
• 0.95mm nozzle diameter offers fine-point suction control
• G1/8 inlet and outlet ports permit simple pneumatic connections
• Rated to 60°C maximum operating temperature for warm environments
• Meets ISO 8573-1:2010 (7:4:4) particulate and oil quality requirements

Applications


• Suitable for pick-and-place in electronics assembly lines
• Ideal for vacuum gripping of small mechanical components
• Used with pneumatic end‑effectors in automation cells
• Can be used for board handling where Compact suction is required
• Used for light vacuum evacuation in electrical test fixtures

What thread standard is used for plumbing the pump into a system?


The connections use G 1/8 thread standard for both inlet and outlet ports to match common pneumatic fittings.

How should it be applied where ambient temperature fluctuates?


It is specified for operation up to 60°C, so installations with higher ambient temperatures or heat sources require additional cooling or relocation.

What indications are there of contamination control capability?


The pump’s conformity to ISO 8573-1:2010 (7:4:4) reflects its handling of Air quality in terms of particle, water and oil classes under that standard.

Is the unit suitable for hazardous-area installations?


It has no hazardous-area certification and should not be used where specific explosion‑proof approvals are required.