Festo Vacuum Pump, 0.95 mm nozzle, -0.89 bar 40.5 L/min, VN series

小計(1 件)*

TWD7,697.00

(不含稅)

TWD8,081.85

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年8月24日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD7,697.00

* 參考價格

RS庫存編號:
202-2414
Distrelec 貨號:
301-69-878
製造零件編號:
VN-10-L-T3-PQ2-VQ2-RO1-B
製造商:
Festo
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Festo

Product Type

Vacuum Pump

Maximum Suction Flow

40.5L/min

Maximum Vacuum Pressure

-0.89bar

Nozzle Diameter

0.95mm

Series

VN

Silencer

Yes

Inlet Thread Standard

QS

Maximum Operating Temperature

50°C

Standards/Approvals

ISO8573-1:2010 (7:4:4), Conforms to RoHS

Hazardous Area Certification

No

COO (Country of Origin):
HU

Festo Series VN Vacuum Pump, 40.5L/min Maximum Suction Flow, -0.89 Bar Maximum Vacuum Pressure - VN-10-L-T3-PQ2-VQ2-RO1-B, Numeric Part Number: 532641


This vacuum pump is a compact, electrically driven device designed to create and maintain negative pressure for handling and process tasks in industrial settings. It operates within standard ambient conditions and integrates easily with pneumatic systems via a quick-connect inlet, offering quiet operation for use close to workstations.

Features and Benefits:


• Maximum suction flow 40.5 L/min delivers steady throughput • Peak vacuum level -0.89 bar supports secure gripping and evacuation • Maximum operating temperature 50°C permits use in warm environments • 0.95mm nozzle enables focused suction for small components • QS inlet thread simplifies installation and tubing changes • Built‑in silencer reduces acoustic disturbance at source

Applications


• Suitable for pick-and-place in Electronic Assembly lines • Ideal for component gripping on automated conveyors • Used for leak detection in small pneumatic circuits • Can be used for vacuum transfer of delicate parts in manufacturing • Suitable for laboratory suction tasks requiring Compact equipment

What filtration or Air quality standard does it meet for system integration?


It conforms to particulate and oil/aerosol limits per ISO 8573-1:2010 class 7:4:4, indicating the level of Air cleanliness expected downstream.

Is the unit appropriate for environments with hazardous-area requirements?


No, it lacks hazardous-area certification and should not be installed where intrinsic safety or explosion protection is required.

How does the silencer affect maintenance access?


The silencer is integrated to attenuate noise while remaining removable to allow inspection or replacement without altering the inlet connection.

Are there restrictions on mounting due to temperature?


The device is rated for continuous operation up to 50°C

ambient or enclosure temperatures above this limit are not recommended.