Lapp UNITRONIC Series Data Cable, 4 Pairs, 8 Cores, 0.34 mm², Screened, 22 AWG, 50m, Screened Shield, Li2YCY Cable
- RS庫存編號:
- 807-9048
- 製造零件編號:
- 0031327
- 製造商:
- Lapp
可享批量折扣
單價 1 管 50 套**
TWD5,648.00
(不含稅)
TWD5,930.40
(含稅)
3 現貨庫存,可於6工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
卷 | 每卷 | 每米** |
---|---|---|
1 - 4 | TWD5,648.00 | TWD112.96 |
5 + | TWD5,506.00 | TWD110.12 |
** 參考價格
- RS庫存編號:
- 807-9048
- 製造零件編號:
- 0031327
- 製造商:
- Lapp
- COO (Country of Origin):
- DE
Unitronic Li2YCY Cable
From Lapp, this Unitronic Li2YCY (TP) cable is a low frequency low capacitance data cable that is well suited for wiring data systems that require a transmission of low, sensitive signals and high bit rates.
The cable has a twisted pair construction, and features a tinned-copper braided screen that protects against signal interference. It also had a PVC sheath, and is optimized for installations with limited flexibility, and for use in dry or damp interiors.
Features and Benefits
Qualified for RS422 and RS485 interfaces
Intended for limited flexible use and for fixed installation
Flame retardant to IEC 60332-1-2
Stranded 7-wire bare copper conductor
Operating temperature in fixed installations: -40°C to +80°C
Operating temperature with occasional flexing: -5°C to +70°C
Applications
Unitronic Li2YCY cable is suitable for signal, control and measuring applications, and is often used in;
Electronic circuits
Computer Systems
Machine design
Office equipment
Accessories
Unitronic cable should be used with accessories that match its capabilities, such as the Lapp range of Skintop MS-HF-M SC cable glands that have low resistance contact as standard.
136-8515 is an M12 Skintop EMC Cable Gland
136-8516 is an M16 Skintop EMC Cable Gland
136-8517 is an M20 Skintop EMC Cable Gland
136-8518 is an M25 Skintop EMC Cable Gland
136-8519 is an M32 Skintop EMC Cable Gland
The cable has a twisted pair construction, and features a tinned-copper braided screen that protects against signal interference. It also had a PVC sheath, and is optimized for installations with limited flexibility, and for use in dry or damp interiors.
Features and Benefits
Qualified for RS422 and RS485 interfaces
Intended for limited flexible use and for fixed installation
Flame retardant to IEC 60332-1-2
Stranded 7-wire bare copper conductor
Operating temperature in fixed installations: -40°C to +80°C
Operating temperature with occasional flexing: -5°C to +70°C
Applications
Unitronic Li2YCY cable is suitable for signal, control and measuring applications, and is often used in;
Electronic circuits
Computer Systems
Machine design
Office equipment
Accessories
Unitronic cable should be used with accessories that match its capabilities, such as the Lapp range of Skintop MS-HF-M SC cable glands that have low resistance contact as standard.
136-8515 is an M12 Skintop EMC Cable Gland
136-8516 is an M16 Skintop EMC Cable Gland
136-8517 is an M20 Skintop EMC Cable Gland
136-8518 is an M25 Skintop EMC Cable Gland
136-8519 is an M32 Skintop EMC Cable Gland
Lapp UNITRONIC Series Data Cable, 22 AWG, Twisted Pair - 0031327
This data cable by Lapp featuring the Li2YCY and UNITRONIC technologies is a versatile solution for various applications in multiple industries. With a twisted pair design and Eca certification, this cable ensures reliable and efficient data transmission.
Features & Benefits
• Twisted pair design with 22 AWG American Wire Gauge for improved signal quality
• Shielded construction with 100 Ω characteristic impedance for enhanced data security
• Flame retardant PVC outer sheath material for added safety and durability
• Screened cable type with S/UTP shield for minimal interference and noise
• Suitable for voltage rating of up to 250V, meeting IEC60332-1 standards
• Shielded construction with 100 Ω characteristic impedance for enhanced data security
• Flame retardant PVC outer sheath material for added safety and durability
• Screened cable type with S/UTP shield for minimal interference and noise
• Suitable for voltage rating of up to 250V, meeting IEC60332-1 standards
Applications
• Ideal for use in industrial automation systems
• Suitable for data transmission in control panels
• Used in communication networks for reliable signal transmission
• Commonly applied in machinery and equipment wiring
• Suitable for data transmission in control panels
• Used in communication networks for reliable signal transmission
• Commonly applied in machinery and equipment wiring
Can it be used in outdoor installations?
Yes, the flame retardant design makes it suitable for outdoor applications.
Will it provide reliable data transmission in high-noise environments?
Yes, the shielded construction ensures minimal interference for reliable performance.
Is it compatible with standard data connectors?
Yes, this data cable is designed to work seamlessly with standard data connectors.
屬性 | 值 |
---|---|
Number of Pairs | 4 |
Cross Sectional Area | 0.34 mm² |
Number of Cores | 8 |
American Wire Gauge | 22 AWG |
Screened/Unscreened | Screened |
Length | 50m |
Shield Type | S/UTP |
CPR Certification | Eca |
Sheath Colour | Grey |
Cable Type | Li2YCY |
Outer Diameter | 8.7mm |
Outer Sheath Material | PVC |
Cable Shape | Twisted Pair |
Characteristic Impedance | 100 Ω |
Minimum Operating Temperature | -40°C |
Fire Behaviour | Flame Retardant |
Shielded/Unshielded | Shielded |
Maximum Operating Temperature | +80°C |
Voltage Rating | 250 V |
Series | UNITRONIC |
Standards Met | IEC60332-1 |