Alpha Wire Pro-Tekt Series Data Cable 1 Pairs 2 Cores 0.35 mm² 50 m Grey Sheath Polyvinyl Chloride

小計(1 卷,共 50 米)*

TWD3,534.00

(不含稅)

TWD3,710.70

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 3 件準備從其他地點送貨
  • 加上 12 件從 2027年1月19日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷
每卷
每米*
1 +TWD3,534.00TWD70.68

* 參考價格

RS庫存編號:
740-4831
製造零件編號:
B964012 GE321
製造商:
Alpha Wire
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Alpha Wire

Number of Pairs

1

Product Type

Data Cable

Cross Sectional Area

0.35mm²

Number of Cores

2

Cable Length

50m

Jacket Colour

Grey

Outside Diameter

4.34mm

Jacket Material

Polyvinyl Chloride

Conductor Type

Copper

Minimum Operating Temperature

-30°C

Maximum Operating Temperature

105°C

Standards/Approvals

CE, CSA Certified, UL

Voltage

300V

Conductor Material

Tin Copper Wire

Fire Behaviour

Flame Retardant

Size of Strands

30AWG

Core Strands

7 x 30AWG

Number of Strands

7

Series

Pro-Tekt

Belden Pro-Tekt Series Data Cable, 50m Cable Length, Grey Jacket - B964012 GE321


This data cable is a single-pair tin-plated copper cable intended for industrial communication and control wiring. Designed for use in automation, electrical and electronic installations, it delivers signal transmission in environments requiring flame-retardant construction and a flexible conductor.

Features & Benefits


• 0.35 mm2 conductor for consistent current-carrying capacity
• Tin-plated copper 7-strand conductor for improved termination
• Flame-retardant PVC jacket for reduced fire propagation risk
• Rated for 300V to suit common low-voltage systems
• Operating range -30 to 105°C for high-temperature environments

**Applications**


• Suitable for control-panel interconnects in manufacturing plants
• Ideal for sensor and actuator wiring in automated systems
• Used with fieldbus and serial communication runs inside cabinets
• Can be used for machine-tool internal signal circuits

How is the conductor arranged internally?


The core comprises a single twisted pair with a 7-strand tin-plated copper conductor and an internal mylar core wrap to maintain pair geometry.

What shielding is provided to reduce interference?


An aluminium/mylar foil shield with an accompanying drain conductor is included to provide coverage and allow easy termination to earth.

How is the outer sheath constructed for installation durability?


The outer sheath is a nominal 0.032 wall PVC with a ripcord for simplified jacket removal during termination.

What electrical characteristics should engineers expect for impedance and capacitance?


Characteristic impedance is nominally 48 Ω, mutual capacitance about 39 pF/ft and ground capacitance about 70 pF/ft at 1 kHz.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。