規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Broyce Control | |
| Supply Voltage | 12 → 48V ac/dc | |
| Mounting Type | DIN Rail | |
| Mode of Operation | Multi Attempt to Start | |
| Time Range | 1 → 60s | |
| Number of Contacts | 1 | |
| Number of Timer Functions | Single | |
| Contact Configuration | SPDT | |
| Time Increment | Seconds | |
| Maximum Current | 8A | |
| Maximum Voltage | 48V ac/dc | |
| Switch Configuration | 2 x SPDT | |
| Terminal Type | Screw | |
| Width | 66.5mm | |
| Power Supply | External | |
| Minimum Voltage | 12V ac/dc | |
| Depth | 89mm | |
| Length | 17.5mm | |
| Series | LMAT | |
| Maximum Operating Temperature | +60°C | |
| Minimum Operating Temperature | -20°C | |
| Time Delay | <100ms | |
| 選取全部 | ||
|---|---|---|
品牌 Broyce Control | ||
Supply Voltage 12 → 48V ac/dc | ||
Mounting Type DIN Rail | ||
Mode of Operation Multi Attempt to Start | ||
Time Range 1 → 60s | ||
Number of Contacts 1 | ||
Number of Timer Functions Single | ||
Contact Configuration SPDT | ||
Time Increment Seconds | ||
Maximum Current 8A | ||
Maximum Voltage 48V ac/dc | ||
Switch Configuration 2 x SPDT | ||
Terminal Type Screw | ||
Width 66.5mm | ||
Power Supply External | ||
Minimum Voltage 12V ac/dc | ||
Depth 89mm | ||
Length 17.5mm | ||
Series LMAT | ||
Maximum Operating Temperature +60°C | ||
Minimum Operating Temperature -20°C | ||
Time Delay <100ms | ||
- COO (Country of Origin):
- GB
The timer is offered with two separate relays. When power is applied, the first relay (Attempts) will energize for the set on time delay period, then de-energize for the set off time delay period. This is classed as the first attempt. The same relay will continue to cycle on and off for the number of attempts set on the adjustment. If all the attempts are allowed to run, at the end of the last on time delay period, the first relay will de-energize and the second relay (Alarm) will energize and remain in this state. Power must be removed and re-applied to restart the function over again.
Multi Attempt to Start
Designed to limit the number of attempts an engine has to start before providing an alarm
Selectable number of attempts (2-8)
Multi-voltage (12 -48VAC/DC)
Single time range (1 - 60s)
2 x SPDT Relay outputs
17.5mm wide, DIN Rail mount
Designed to limit the number of attempts an engine has to start before providing an alarm
Selectable number of attempts (2-8)
Multi-voltage (12 -48VAC/DC)
Single time range (1 - 60s)
2 x SPDT Relay outputs
17.5mm wide, DIN Rail mount
相關連結
- Broyce Control DIN Rail Mount Timer Relay 1-Contact 1-Function, SPDT
- Broyce Control DIN Rail Mount Timer Relay 24V ac/dc 2 → 60s SPDT
- Broyce Control DIN Rail Mount Time Delay Relay 1-Contact 1-Function, SPDT
- Broyce Control DIN Rail Mount Time Delay Relay 1-Contact 1-Function, SPDT
- Broyce Control DIN Rail Mount Timer Relay 1-Contact 1-Function, SPDT
- Omron H3Y-2 Series Plug In Timer Relay 8-Contact 1-Function
- RS PRO Plug In Timer Relay 4-Contact 1-Function, 4PDT
- RS PRO Plug In Timer Relay 4-Contact 1-Function, 4PDT