Omron H3DK Series DIN Rail Timer Relay, 2-Contact, 24 to 240 V dc 100V ac, 120 V ac, 1 to 120 s, Multifunction-Function,
- RS庫存編號:
- 177-0082
- 製造零件編號:
- H3DK-HCL AC100-120
- 製造商:
- Omron
小計(1 件)*
TWD3,150.00
(不含稅)
TWD3,307.50
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 4 件從 2026年5月19日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD3,150.00 |
* 參考價格
- RS庫存編號:
- 177-0082
- 製造零件編號:
- H3DK-HCL AC100-120
- 製造商:
- Omron
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Omron | |
| Product Type | Timer Relay | |
| Mount Type | DIN Rail | |
| Function | Valve, Power Off Delay, Timer | |
| Time Range | 1 to 120 s | |
| Number of Contacts | 2 | |
| Number of Timer Functions | Multifunction | |
| Switching Voltage | 250V ac | |
| Contact Configuration | SPDT | |
| IP Rating | IP20, IP30 | |
| Supply AC Voltage | 100, 120V ac | |
| Contact Current | 5A | |
| Supply DC Voltage | 24 to 240 V dc | |
| Minimum Operating Temperature | -20°C | |
| Terminal Type | Screw | |
| Maximum Operating Temperature | 55°C | |
| Length | 22.5mm | |
| Standards/Approvals | UL 508, CSA C22.2 No. 14, LR, EN 50274, EN 61812-1, IEC 60664-1, CE, CCC | |
| Width | 79mm | |
| Height | 100mm | |
| Series | H3DK | |
| 選取全部 | ||
|---|---|---|
品牌 Omron | ||
Product Type Timer Relay | ||
Mount Type DIN Rail | ||
Function Valve, Power Off Delay, Timer | ||
Time Range 1 to 120 s | ||
Number of Contacts 2 | ||
Number of Timer Functions Multifunction | ||
Switching Voltage 250V ac | ||
Contact Configuration SPDT | ||
IP Rating IP20, IP30 | ||
Supply AC Voltage 100, 120V ac | ||
Contact Current 5A | ||
Supply DC Voltage 24 to 240 V dc | ||
Minimum Operating Temperature -20°C | ||
Terminal Type Screw | ||
Maximum Operating Temperature 55°C | ||
Length 22.5mm | ||
Standards/Approvals UL 508, CSA C22.2 No. 14, LR, EN 50274, EN 61812-1, IEC 60664-1, CE, CCC | ||
Width 79mm | ||
Height 100mm | ||
Series H3DK | ||
- COO (Country of Origin):
- ID
Omron H3DK Series Timer Relay, 1 to 120s Time Range, SPDT Contact Configuration - H3DK-HCL AC100-120
This timer relay provides configurable time-delay functionality for industrial control systems, enabling delayed switching and valve power-off sequencing within automation panels. It is intended for DIN-rail mounting and suits electrical, electronic and mechanical installations requiring Compact time control and a changeover contact for load switching.
Features and Benefits:
• SPDT contact rated for 5A delivers direct load-switching capability
• Multifunction timing covers 1 to 120 s for versatile delay selection
• Accepts 100/120V AC or 24–240V DC supplies for flexible power options
• Screw terminals ensure secure, serviceable wiring connections
• 250V AC switching voltage supports common AC load requirements
• UL508, CSA, EN and IEC standards certification confirms industrial acceptability
• Multifunction timing covers 1 to 120 s for versatile delay selection
• Accepts 100/120V AC or 24–240V DC supplies for flexible power options
• Screw terminals ensure secure, serviceable wiring connections
• 250V AC switching voltage supports common AC load requirements
• UL508, CSA, EN and IEC standards certification confirms industrial acceptability
Applications
• Suitable for valve power-off delay operations in pneumatic systems
• Ideal for pump and motor control panels requiring timed shut-off
• Used with PLCs for auxiliary timing and interlock sequences
• Can be used for machinery safety delays during stop procedures
• Ideal for pump and motor control panels requiring timed shut-off
• Used with PLCs for auxiliary timing and interlock sequences
• Can be used for machinery safety delays during stop procedures
What mounting method is required for panel installation?
It clips onto a standard DIN rail to allow Rapid fitting and replacement within control cabinets.
Which environmental limits affect placement inside enclosures?
It operates between -20 °C and 55 °C, so enclosures should maintain ambient temperatures within this range.
How many switching contacts are available for control circuits?
There are two contacts arranged as a single changeover contact providing one switching output.
What protection ratings describe suitability for interior installations?
The product has IP20 and IP30 ratings, indicating protection against finger access and limited solid ingress for indoor use.
How is wiring secured and maintained during service?
Terminals are screw type to permit firm conductor clamping and straightforward retightening during maintenance.
相關連結
- Omron H3DK Series DIN Rail Timer Relay 12 to to 240 V dc 100V ac 1 to 12 s
- Omron H3DK Series DIN Rail Timer Relay 12 V dc Multifunction-Function, SPDT Switch
- Omron H3YN Series Timer Relay 100 to 120 V ac 100V ac 0.1 to 600 min
- Omron H3YN Series Timer Relay 100 to 120 V ac 100V ac 0.1 to 600 s 4PDT
- Omron H3YN Series Timer Relay 100 to 120 V ac 100V ac 0.1 to 600 s DPDT
- Omron H3CR Series DIN Rail Timer Relay 100 to 125 V dc 100V ac 0.5 to 120 s,
- Omron H3DK Series DIN Rail Timer Relay 12 to to 240 V dc 12V ac Multifunction-Function,
- Omron H3DK Series DIN Rail Timer Relay 12 to to 240 V dc 12V ac Multifunction-Function,