United Automation DMFC36, Driver Module
- RS庫存編號:
- 847-4715
- 製造零件編號:
- DMFC36
- 製造商:
- United Automation
可享批量折扣
小計(1 件)*
TWD13,343.00
(不含稅)
TWD14,010.15
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 3 件從 2026年3月02日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 2 | TWD13,343.00 |
| 3 + | TWD13,009.00 |
* 參考價格
- RS庫存編號:
- 847-4715
- 製造零件編號:
- DMFC36
- 製造商:
- United Automation
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | United Automation | |
| Product Type | Driver Module | |
| Mount Type | DIN Rail | |
| Pin Count | 9 | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 65°C | |
| Series | DFMC36 | |
| Standards/Approvals | European Low Voltage Directive, EN61010-1, EN 50 081 part 2, European EMC Directive, EN61000-6-2 | |
| Automotive Standard | No | |
| 選取全部 | ||
|---|---|---|
品牌 United Automation | ||
Product Type Driver Module | ||
Mount Type DIN Rail | ||
Pin Count 9 | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 65°C | ||
Series DFMC36 | ||
Standards/Approvals European Low Voltage Directive, EN61010-1, EN 50 081 part 2, European EMC Directive, EN61000-6-2 | ||
Automotive Standard No | ||
Multi Mode, Phase-Angle & Single/Dual Cycle Burst Firing Circuit, DMFC-36
The DMFC-36 module has been designed to offer Phase-Angle or Burst Fire Control in firing a thyristor assembly or complete thyristor controller for driving resistive loads. In Single-Cycle or Dual-Cycle mode, these modules use the fastest burst rates possible, providing very accurate control and minimising Harmonic distortion & Flicker within the system.
Includes a Transformer
Standard Din Rail Mount
On Board Indication of Power, Burst-Rates & Fault Conditions
Phase-Angle, or Burst Fire Control
Single-Cycle / Dual Cycle Burst Fire modes of control or adjustable Standard Burst Firing
Soft-start (1 to 30 seconds)
Inhibit Input
Wide Range of Control Options: 0-5V, 0-10V, 1-5V, 2-10V, 0-20mA, 4-20mA, Manual Potentiometer
Isolated Pulse transformer outputs
On Board Protection Fuse
The number of complete mains cycles during fixed repeating periods (typically 1 to 10 seconds) is varied, thus altering the duty cycle or on-/off-time ratio. Trigger pulses coincide with the zero-crossing times of the mains supply thus ensuring no RFI is produced when using resistive loads.
相關連結
- United Automation MAT, Thyristor Trigger Module
- United Automation FC11BL, Thyristor Trigger Module
- United Automation FC11AL, Phase-Angle Firing Module
- United Automation STOM-1, Thyristor Trigger Module
- United Automation FC36M, Three Phase Thyristor Driver 500 mA
- United Automation AFM11, Universal Phase Angle Trigger Module
- United Automation CM-FC36 (M/MV), Commander Module
- United Automation A34512 0.075 A 1 A