RS PRO RS192/0816 Type K Exposed Junction Thermocouple 10 m Length, -75 °C → 250 °C Max

可享批量折扣

小計(1 件)*

TWD850.00

(不含稅)

TWD892.50

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 15 件準備從其他地點送貨
  • 加上 40 件從 2026年7月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。

單位
每單位
1 - 9TWD850.00
10 - 49TWD816.00
50 +TWD670.00

* 參考價格

RS庫存編號:
847-9735
Distrelec 貨號:
304-19-886
製造商:
RS PRO
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

RS PRO

Thermocouple Type

K

Product Type

Exposed Junction Thermocouple

Probe Length

10m

Maximum Temperature Sensed

250°C

Probe Material

PFA

Series

RS192/0816

Terminal Type

Exposed Welded Tip

Cable Length

10m

Standards/Approvals

ANSI, RoHS Compliant

Minimum Temperature Sensed

-75°C

COO (Country of Origin):
GB

RS Pro ANSI Type K & T Fine Wire Exposed Junction Thermocouples


From RS Pro a range of Type K and Type T fine wire temperature sensing thermocouples ithat meet ANSI MC96.1 stanards with class 1 tolerance for optimum accuracy. These Type K and type T wire temperature sensors consist of a durable Teflon PFA insulated twin-twisted lead and a single element exposed welded junction for a fast response time.

How does a Thermocouple Work?


A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

What is a Welded Exposed Junction?


A welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures

Features and Benefits


• ANSI MC96.1 class 1 tolerance for optimum accuracy

• Class 1 cable specification in accordance with BS EN 60584-3:2008

• Exposed welded junction for fast response

• Durable Teflon PFA insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility

• Temperature ranges from -75 to +250°C

Applications


These K Type and T type fine wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications