Endress+Hauser TMT72 Temperature Transmitter RTD, Thermocouple Input 42V, 85 °C, -40 °C

小計(1 件)*

TWD15,668.00

(不含稅)

TWD16,451.40

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 8 件從 2026年8月10日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD15,668.00

* 參考價格

RS庫存編號:
287-1874
製造零件編號:
TMT72-AAA2AAAA1
製造商:
Endress+Hauser
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Endress+Hauser

Input Type

RTD, Thermocouple

Product Type

Temperature Transmitter

Output Type

Analogue Output

Minimum Temperature Input

-50°C

Maximum Temperature Input

200°C

Series

TMT72

Maximum Supply Voltage

42V

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

85°C

Hazardous Area Certification

No

Standards/Approvals

CE mark

COO (Country of Origin):
DE

Endress+Hauser TMT72 Series Temperature Transmitter, 200°C Maximum Temperature Input, -50°C Minimum Temperature Input - TMT72-AAA2AAAA1


This temperature transmitter converts resistance and thermocouple sensor signals into an analogue output for process use. It is designed for industrial installations where compact form and CE conformity are required, operating across ambient conditions from low sub-zero to elevated temperatures. The device accepts a broad input range and supplies a standardised output suitable for control and monitoring systems.

Features and Benefits:


• Accepts RTD and thermocouple inputs for flexible sensor selection
• Outputs 4-20mA analogue signal for conventional process integration
• Measures process temperatures from -50 to 200°C for wide thermal range
• Operates at ambient conditions from -40 to 85°C for varied environments
• Maximum supply voltage 42V enabling compatibility with common loops

Applications


• Suitable for loop-powered temperature measurement in plant rooms
• Ideal for sensor signal conversion in control cabinets
• Used for process monitoring in manufacturing lines
• Can be used for temperature feedback to PLCs and DCS

What approvals does the unit carry for installation certainty?


It bears the CE mark indicating conformity with applicable European safety and EMC requirements.

Is the transmitter certified for use in hazardous atmospheres?


No, it is not rated for hazardous-area installations and should be confined to non-hazardous locations.

What physical form factor should I account for during mounting?


The housing has a nominal diameter of 44 mm and a depth of 24.1 mm for panel or head-mount integration.

What electrical input constraints must be observed?


Ensure loop supply does not exceed the maximum supply voltage of 42V to prevent damage.