Festo EMMT-ST Series Servo Motor Stepper Motor 48V, 1.12Nm Torque, 1.8 °

N

小計(1 件)*

TWD7,235.00

(不含稅)

TWD7,596.75

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月14日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD7,235.00

* 參考價格

RS庫存編號:
827-244
製造零件編號:
EMMT-ST-57-M-R
製造商:
Festo
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Festo

Sub Type

Servo Motor

Product Type

Stepper Motor

Step Angle

1.8°

Holding Torque

1.12Nm

Voltage

48V

Current Rating

5.4A

IP Rating

IP40, IP65

Number of Pole Pairs

50

Resistance Per Phase

0.17Ω

Standards/Approvals

cULus, EU RoHS, RCM, UL E342973

Output Speed

2600rpm

Detent Torque

1.12nm

Series

EMMT-ST

COO (Country of Origin):
BG

Festo EMMT-ST Series Stepper Motor, 48V Nominal Operating Voltage, 1.12Nm Holding Torque - EMMT-ST-57-M-R, Numeric Part Number: 8156173


This stepper motor provides precise incremental motion control for industrial automation and positioning tasks. Designed for continuous-duty operation, it runs on 48 V DC and delivers a fine 1.8° step angle for accurate indexing. The motor supports installation at a range of ambient temperatures and altitudes with appropriate derating, and its housing offers enhanced protection against environmental exposure.

Features and Benefits:


• 1.8° step angle enables accurate positional control
• 2600 rpm output speed supports moderate-speed motion tasks
• 5.4 A nominal current gives sustained torque for continuous duty
• 0.17 Ω resistance per phase reduces voltage drop under load
• IP65-rated motor housing protects connections from contaminants

Applications


• Suitable for precision conveyor indexing in manufacturing
• Used for Camera positioning and inspection systems
• Ideal for rotary actuation in assembly stations
• Can be used for valve positioning in process plants
• Used with motion controllers in laboratory automation

What maximum ambient temperature can it tolerate?


It operates between -15 °C and 40 °C and may be used up to 80 °C with a derating of -2% per °C.

What are the current limits for continuous and Peak operation?


Continuous stall current is 6.6 A, nominal current is 5.4 A and Peak current is 8 A.

How does altitude affect performance?


Installation up to 4,000 m is possible

above 1,000 m apply derating of -1.0% per 100 m.

What mechanical loads can the shaft accept?


Permissible axial load is 15 N and permissible radial load is 75 N.