Lapp ÖLFLEX CLASSIC FD 810 Control Cable, 25 Cores, 1 mm² CSA 18 AWG, Unscreened, 25 m, Grey Polyvinyl Chloride Sheath

小計(1 卷,共 25 米)*

TWD14,268.00

(不含稅)

TWD14,981.40

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 44 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
每卷
每米*
1 +TWD14,268.00TWD570.72

* 參考價格

RS庫存編號:
387-6967
製造零件編號:
0026139
製造商:
Lapp
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Lapp

Product Type

Control Cable

Series

ÖLFLEX CLASSIC FD 810

Number of Cores

25

Cross Sectional Area

1 mm²

Conductor Material

Copper

Jacket Material

Polyvinyl Chloride

Jacket Colour

Grey

Screened/Unscreened

Unscreened

Cable Length

25m

Outside Diameter

17.8 mm

Voltage

500 V

Minimum Operating Temperature

0°C

Conductor Type

Stranded

Standards/Approvals

ECA

Maximum Operating Temperature

70°C

American Wire Gauge

18AWG

Fire Behaviour

Flame Retardant

Core Strands

56

COO (Country of Origin):
DE

LAPP ÖLFLEX CLASSIC FD 810 Series Control Cable, 1mm² Cross Sectional Area, 25 Cores - 0026139


This control cable is designed for versatile applications in the automation and mechanical sectors. With a length of 25m and a round shape, it includes 25 cores with a cross-sectional area of 1mm². The cable features a durable PVC outer sheath and bare copper conductors, accommodating various environments and ensuring reliable operation in measuring, control, and regulating circuits.

Features & Benefits


• Highly flexible design ensures ease of installation

• Low particle emission suitable for power chain use

• Rated for 300/500 V AC, providing robust electrical performance

• Flame-retardant properties according to IEC 60332-1-2 standards

• Capable of enduring up to 5 million bending cycles

Applications


• Utilised in assembly and production lines for effective operation

• Suitable for powering chain where flexibility is vital

• Ideal for use in environments with damp or wet conditions

• Amendable for outdoor use with UV protection within specified temperatures

What materials are used for the construction of the cable?


The cable consists of bare copper conductors, providing excellent conductivity, while the core insulation and outer sheath are made from durable PVC to ensure both flexibility and resistance to environmental conditions.

What is the minimum bend radius for this cable?


For flexible applications, the minimum bend radius should be 7.5 times the outer diameter, while for fixed installations, it is 4 times the outer diameter. This ensures the integrity and performance of the cable under varying conditions.

How does this cable perform in high-temperature environments?


It is designed to operate effectively in temperatures ranging from 0°C to +70°C in flexible applications. The PVC insulation contributes to its high-temperature stability while maintaining flexibility for dynamic use.

Standards

VED 0295, Part 6