Dold LG 5929 Series Output Module, 2 Inputs, 5 Outputs, 24V ac/dc, 5 NO/NC

此圖片僅供參考,請參閲產品詳細資訊及規格

小計(1 件)*

TWD6,515.00

(不含稅)

TWD6,840.75

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 5 件從 2026年4月27日 起發貨
  • 加上 3 件從 2026年4月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD6,515.00

* 參考價格

RS庫存編號:
500-3436
製造零件編號:
LG5929.60/61 AC/DC24V
製造商:
Dold
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Dold

Series

LG 5929

Product Type

Output Module

Sub Type

Output Module

Mount Type

DIN Rail

For Use With

LG 5929

Supply Voltage

24V ac/dc

Normal State Configuration

5 NO/NC

Number of Inputs

2

Number of Outputs

5

Terminal Type

Screw

Standards/Approvals

UL, CE

Hazardous Area Certification

NO

COO (Country of Origin):
DE

Dold Emergency Stop Module


The Dold LG5929 series emergency stop module has a single-channel 5NO/1NC normal state configuration. This extension unit has a supply voltage of 24VDC/AC.

Features and Benefits


1 semiconductor output

Line fault detection on on-button

Manual restart or automatic restart, switch S2

With or without cross fault monitoring in the E-stop loop, switch S1

Cross fault monitoring in the E-stop loop

LED indicator for state of operation

LED indicator for channel 1 and 2

Removable terminal strips

Wire connection also 2mm x 1.5mm2 stranded ferruled, or 2mm x 2.5mm2

Fixed screw terminals connection

Applications


Emergency stop circuits on machines

Monitoring of safety gates

Certifications


CE certified

TUV certified

cULus listed

CCC certified

IEC/EN 62061

IEC/EN 61508 category 4

EN 954-1

LG 5925 - Emergency stop module, LG 5929 - Expansion module


Applications


Emergency stop and expansion modules for
- Machine emergency stop switching
- Monitoring sliding grill guards

General data


Safety category 4 in accordance with EN954-1

Operating status indicator

22.5 mm overall width

Emergency stop module LG 5925.48


1 or 2-channel configuration

Line termination recognition on the ON button

with or without crossover recognition

Expansion module LG 5929.60


Use only with a higher-level emergency stop module

Redundant and force guided contacts

1-channel configuration

Approvals

CE

Standards

EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1, IEC / EN 60204-01,
EN 954-1