SICK FXL1 Series Safety Controller, 2 Safety Outputs, 24V dc

小計(1 件)*

TWD19,818.00

(不含稅)

TWD20,808.90

(含稅)

Add to Basket
選擇或輸入數量
有限的庫存
  • 1 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD19,818.00

* 參考價格

RS庫存編號:
285-9515
製造零件編號:
FXL1-SPLMAA00
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Series

FXL1

Product Type

Safety Controller

Number of Safety Outputs

2

Safety Category

4

Supply Voltage

24V dc

Contact Current

100mA

Depth

45mm

Terminal Type

M12 Connector

Width

48mm

Length

194.4mm

IP Rating

IP69K, IP67, IP65

COO (Country of Origin):
MY

SICK FXL1 Series Safety Controller, 24V DC Supply Voltage, 100mA Contact Current - FXL1-SPLMAA00


This safety controller is a compact, industrial device designed to manage access and locking functions in automated systems. It provides safe semiconductor outputs for monitoring actuators and interlock states and operates from a 24V DC supply. The unit is intended for integration with M12-connected equipment and supports series wiring topologies with diagnostic options, enabling streamlined installation in control cabinets or via field cabling.

Features and Benefits:


• SIL3 safety integrity level supporting high-risk applications
• Category 4 performance delivering Advanced functional safety
• Two PNP safety outputs offering cross-circuit monitoring
• Self-monitoring outputs limited to 100mA protecting downstream loads
• IP65/IP67/IP69K enclosure enabling harsh-environment operation

Applications


• Used with RFID safety locking devices for guarded access control
• Suitable for machine tool guarding with locking monitoring
• Ideal for series-connected safety devices requiring diagnostics
• Can be used in washdown zones due to high protection rating

What supply voltage range does the unit accept?


It runs on 24V DC with an operating range of 19.2V DC to 28.8V DC.

How are the field connections implemented?


Connections use an 8-pin M12 plug connector with a stainless-steel coupling nut.

What are the response and release characteristics?


Typical response time is ≤150 MS and release time is ≤350 MS in a safe series connection.

How does the device indicate status and faults?


LEDs provide status display and a diagnostics indicator conveys application-level information.

What environmental extremes can it tolerate?


It operates between -20°C and +55°C and resists vibration and shock per standard test criteria.