Eaton RCD, 20A, 2 Pole, 30mA, Type C, 230V
- RS庫存編號:
- 922-8737
- 製造零件編號:
- 236249 PKNM-20/1N/C/003-A-MW
- 製造商:
- Eaton
小計(1 件)*
TWD4,053.00
(不含稅)
TWD4,255.65
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 7 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD4,053.00 |
* 參考價格
- RS庫存編號:
- 922-8737
- 製造零件編號:
- 236249 PKNM-20/1N/C/003-A-MW
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Circuit Breaker Type | RCD | |
| Current Rating | 20A | |
| Number of Poles | 2 | |
| Range | PKNM | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Voltage Rating | 230V | |
| Standards Met | CE | |
| Break Time | Instantaneous | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Reset Actuator Type | Toggle Switch | |
| Overall Dimensions | 35 x 65.5 x 80mm | |
| Mounting Style | DIN Rail Mount | |
| Rated AC Voltage | 230V | |
| Overall Depth | 80mm | |
| Overall Length | 35mm | |
| Earth Leakage Protection Type | A | |
| Terminal Contact Type | Screw | |
| Overall Width | 65.5mm | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Circuit Breaker Type RCD | ||
Current Rating 20A | ||
Number of Poles 2 | ||
Range PKNM | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Voltage Rating 230V | ||
Standards Met CE | ||
Break Time Instantaneous | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Reset Actuator Type Toggle Switch | ||
Overall Dimensions 35 x 65.5 x 80mm | ||
Mounting Style DIN Rail Mount | ||
Rated AC Voltage 230V | ||
Overall Depth 80mm | ||
Overall Length 35mm | ||
Earth Leakage Protection Type A | ||
Terminal Contact Type Screw | ||
Overall Width 65.5mm | ||
- COO (Country of Origin):
- RO
Eaton RCD, Contact Position Indicator, DIN Rail Mounting - PKNM Series - 236249 PKNM-20/1N/C/003-A-MW
Stop electrical hazards in their tracks with this RCD from Eaton. A trip sensitivity of 30mA means it protects personnel from even very small current leakages. This makes it ideal for safeguarding against ground faults in settings such as care homes, offices and shops. Type-C tripping characteristics permit loads that need an inrush current to work properly, but the device will trip instantly if the current exceeds five to ten times its 20A rating. As you can mount this RCD on a DIN rail, installation is done in a flash.
Features & Benefits
• Rated voltage of 230V AC for compatibility with the UK mains supply
• Red and green contact position indicators let you check on status at a glance
• Screw terminals help you make quick and secure electrical connections
• Toggle switch allows you to quickly re-energise the circuit once the fault is identified and fixed
• Red and green contact position indicators let you check on status at a glance
• Screw terminals help you make quick and secure electrical connections
• Toggle switch allows you to quickly re-energise the circuit once the fault is identified and fixed
How many poles does this RCD have?
This RCD is a single-pole plus neutral device. It offers a suitable level of protection for houses and small commercial premises where a single-phase system is used.
Note
Eaton formerly known as Moeller