Eaton RCD, 10A, 2 Pole, 30mA, Type C, 230V
- RS庫存編號:
- 922-8715
- 製造零件編號:
- 236082 PKNM-10/1N/C/003-A-MW
- 製造商:
- Eaton
小計(1 件)*
TWD4,053.00
(不含稅)
TWD4,255.65
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 163 件準備從其他地點送貨
- 加上 39 件從 2026年3月10日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD4,053.00 |
* 參考價格
- RS庫存編號:
- 922-8715
- 製造零件編號:
- 236082 PKNM-10/1N/C/003-A-MW
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Circuit Breaker Type | RCD | |
| Current Rating | 10A | |
| Number of Poles | 2 | |
| Range | PKNM | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Voltage Rating | 230V | |
| Standards Met | CE | |
| Break Time | Instantaneous | |
| Mounting Style | DIN Rail Mount | |
| Rated AC Voltage | 230V | |
| Overall Dimensions | 35 x 65.5 x 80mm | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Overall Length | 35mm | |
| Terminal Contact Type | Screw | |
| Overall Depth | 80mm | |
| Overall Width | 65.5mm | |
| Reset Actuator Type | Toggle Switch | |
| Earth Leakage Protection Type | A | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Circuit Breaker Type RCD | ||
Current Rating 10A | ||
Number of Poles 2 | ||
Range PKNM | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Voltage Rating 230V | ||
Standards Met CE | ||
Break Time Instantaneous | ||
Mounting Style DIN Rail Mount | ||
Rated AC Voltage 230V | ||
Overall Dimensions 35 x 65.5 x 80mm | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Overall Length 35mm | ||
Terminal Contact Type Screw | ||
Overall Depth 80mm | ||
Overall Width 65.5mm | ||
Reset Actuator Type Toggle Switch | ||
Earth Leakage Protection Type A | ||
- COO (Country of Origin):
- RO
Eaton RCD, Screw Terminals, Front Toggle Switch - PKNM Series - 236082 PKNM-10/1N/C/003-A-MW
Keep your people safe from electric shocks with this RCD from Eaton. Its type-C tripping characteristics make it suitable for protecting more powerful motors. If the current exceeds two to five times the rated load, the unit will trip and shut off the power before any damage can be done. Once you've found and rectified the fault, simply flick the toggle switch to reset the RCD and get up and running again.
Features & Benefits
• Screw terminals help you quickly make secure electrical connections
• Red and green contact position indicators let you check the status at a glance
• Single-pole plus neutral configuration means it protects both the phase and neutral conductors in single-phase loads such as lighting
• 10A current rating to protect circuits with the same input
What's the difference between an RCD and an MCB?
An RCD (residual current device) is a safety device that detects and disconnects power when it senses a leakage of current. An MCB (miniature circuit breaker) is designed to protect circuits from overcurrents and short circuits by interrupting the flow of current. While both enhance electrical safety, an RCD focuses on keeping people safe rather than protecting the circuit.
Note
Eaton formerly known as Moeller