Eaton RCCB, 63A, 4 Pole, 300mA, Type B
- RS庫存編號:
- 183-3556
- 製造零件編號:
- 167906 FRCDM-63/4/03-G/BFQ
- 製造商:
- Eaton
單價 個**
TWD52,774.00
(不含稅)
TWD55,412.70
(含稅)
當前暫無庫存,可於02/02/2025發貨,6 工作日送達。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | TWD52,774.00 |
** 參考價格
- RS庫存編號:
- 183-3556
- 製造零件編號:
- 167906 FRCDM-63/4/03-G/BFQ
- 製造商:
- Eaton
- COO (Country of Origin):
- CZ
Eaton Residual Current Circuit Breakers (RCDs) - FRCdM Series Types B, B+ and Bfq
The FRCdM series of residual current devices from Eaton form part of the xEffect range providing the highest RCD protection for both people and appliances. These devices allow for permanent indication of actual electrical leakage with built in digital features.These types B, B+ and Bfq RCCBs detect AC pulsating, DC residual and smooth DC residual currents.
Type B RCCBs are the standard type and are sensitive to all residual current flows up to 1 kHZ. Type B+ devices are sensitive to all residual currents while also being equipped with a special tripping curve that limits the trip current to max. 420 mA for frequencies up to 20 kHz (Type B+ also meets superior fire protection regulations according to VDE 0664-400). Type Bfq devices meanwhile can tolerate system-induced earth leakage currents at higher frequencies up to 50 kHz.
Type B RCCBs are the standard type and are sensitive to all residual current flows up to 1 kHZ. Type B+ devices are sensitive to all residual currents while also being equipped with a special tripping curve that limits the trip current to max. 420 mA for frequencies up to 20 kHz (Type B+ also meets superior fire protection regulations according to VDE 0664-400). Type Bfq devices meanwhile can tolerate system-induced earth leakage currents at higher frequencies up to 50 kHz.
Features and Benefits
All-current sensitive residual current device for fault or additional protection
Digital Features
System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents
Integrated auxiliary contact
Local Indication through 3 LEDs
4-pole types can also be used as 2-pole devices for photovoltaic applications
New level of accuracy - reduced unwanted tripping
No monthly test required
Comprehensive range of accessories
Real contact position indicator
Fault current tripping indicator
Automatic re-setting possible
Transparent designation plate
Digital Features
System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents
Integrated auxiliary contact
Local Indication through 3 LEDs
4-pole types can also be used as 2-pole devices for photovoltaic applications
New level of accuracy - reduced unwanted tripping
No monthly test required
Comprehensive range of accessories
Real contact position indicator
Fault current tripping indicator
Automatic re-setting possible
Transparent designation plate
What type of RCD do I need?
An RCD is a protective and potentially life saving device designed to keep electrical installations protected from nuisance trips, short circuits and overloads, whilst also protecting against electric shocks and electrocution when there is bare or faulty wiring, or earth leakage. The device will automatically cut out the power supply when a fault is detected.
Fixed RCDs are commonly installed in a fuse box and can protect multiple circuits. RCDs located within a consumer unit are mostly passive which allows household appliances to re-establish normal operation when the circuit power is reset.
Socket-Outlet RCDs provide individual protection to the person who is in contact with the equipment, making them an integral tool for electricians. They can be used in place of a standard socket outlet. Socket-outlet RCDs are either active or passive. They are latching in operation so are not ideal for power tools which do not require a restart when the circuit is restored.
Portable RCD plugs also only provide individual protection to the person who is in contact with the equipment. They plug-in to any standard socket, and the appliance is then plugged into the RCD. Portable RCDs are mostly active and unlatch when any abnormality is detected. Ideally suited for use with outside power tools which could become dangerous if they were suddenly reactivated.
Fixed RCDs are commonly installed in a fuse box and can protect multiple circuits. RCDs located within a consumer unit are mostly passive which allows household appliances to re-establish normal operation when the circuit power is reset.
Socket-Outlet RCDs provide individual protection to the person who is in contact with the equipment, making them an integral tool for electricians. They can be used in place of a standard socket outlet. Socket-outlet RCDs are either active or passive. They are latching in operation so are not ideal for power tools which do not require a restart when the circuit is restored.
Portable RCD plugs also only provide individual protection to the person who is in contact with the equipment. They plug-in to any standard socket, and the appliance is then plugged into the RCD. Portable RCDs are mostly active and unlatch when any abnormality is detected. Ideally suited for use with outside power tools which could become dangerous if they were suddenly reactivated.
Eaton 63A Type G/Bfq Residual Current Circuit Breaker - FRCDM-63/4/03-G/BFQ
Digital residual current circuit-breaker, 63A current rating, 4 Pole, 300mA trip sensitivity, type G/Bfq
Note
Eaton formerly known as Moeller
屬性 | 值 |
---|---|
Circuit Breaker Type | RCCB |
Current Rating | 63A |
Number of Poles | 4 |
Range | FRCdM |
Trip Sensitivity | 300mA |
Tripping Characteristics | Type B |
Rated AC Voltage | 240V |
Mounting Style | DIN Rail Mount |
Rated DC Voltage | 220V |
Break Time | Time Delay |
Overall Dimensions | 70 x 76 x 80mm |
Overall Length | 70mm |
Overall Depth | 80mm |
Overall Width | 76mm |
Terminal Contact Type | Screw |
Breaking Capacity at Maximum Voltage Rating | 630 A |