Eaton FRCdM Series Residual Current Circuit Breaker, 40 A, 4-Pole, 300 mA, Type B, 10 kA, 220 V dc 240 V ac
- RS庫存編號:
- 183-3551
- Distrelec 貨號:
- 300-42-675
- 製造零件編號:
- 167901 FRCDM-40/4/03-S/B
- 製造商:
- Eaton
小計(1 件)*
TWD42,175.00
(不含稅)
TWD44,283.75
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 1 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD42,175.00 |
* 參考價格
- RS庫存編號:
- 183-3551
- Distrelec 貨號:
- 300-42-675
- 製造零件編號:
- 167901 FRCDM-40/4/03-S/B
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Range | FRCdM | |
| Series | FRCdM | |
| Trip Sensitivity | 300mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type B | |
| Standards/Approvals | IEC 61373, EN 45545-2, IEC/EN 61008 | |
| Terminal Type | Screw | |
| Width | 70 mm | |
| Depth | 70.5mm | |
| Height | 80mm | |
| Breaking Capacity | 10kA | |
| Tripping Mechanism | Electromagnetic | |
| Application | Industrial | |
| Earth Leakage Protection Type | Type B | |
| Rated AC Voltage | 240 V ac | |
| Rated DC Voltage | 220 V dc | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Range FRCdM | ||
Series FRCdM | ||
Trip Sensitivity 300mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type B | ||
Standards/Approvals IEC 61373, EN 45545-2, IEC/EN 61008 | ||
Terminal Type Screw | ||
Width 70 mm | ||
Depth 70.5mm | ||
Height 80mm | ||
Breaking Capacity 10kA | ||
Tripping Mechanism Electromagnetic | ||
Application Industrial | ||
Earth Leakage Protection Type Type B | ||
Rated AC Voltage 240 V ac | ||
Rated DC Voltage 220 V dc | ||
- COO (Country of Origin):
- CZ
Digital residual current circuit-breaker, 40A, 4p, 300mA, type S/B
All-current sensitive RCCB for fault or additional protection
Digital Features
System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents
Integrated auxiliary contact
Local Indication through 3 LEDs
4-pole types can also be used as 2-pole devices for photovoltaic applications
New level of accuracy -> reduced unwanted tripping
No monthly test required
Comprehensive range of accessories
Real contact position indicator
Fault current tripping indicator
Automatic re-setting possible
Transparent designation plate
Note