Eaton xEffect Series Residual Current Circuit Breaker, 80 A, 4-Pole, 300 mA, Type B, 800 A 415 V ac
- RS庫存編號:
- 242-956
- 製造零件編號:
- 187809 FRCMM-80/4/03-S/B
- 製造商:
- Eaton
小計(1 件)*
TWD78,951.00
(不含稅)
TWD82,898.55
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年5月12日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD78,951.00 |
* 參考價格
- RS庫存編號:
- 242-956
- 製造零件編號:
- 187809 FRCMM-80/4/03-S/B
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 80 A | |
| Number of Poles | 4 | |
| Series | xEffect | |
| Range | FRCmM | |
| Trip Sensitivity | 300mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type B | |
| Standards/Approvals | IEC/EN 61008 IEC/EN 62423 | |
| Terminal Type | Twin-Purpose Terminal | |
| Height | 80mm | |
| Width | 70 mm | |
| Depth | 76mm | |
| Breaking Capacity | 800A | |
| Earth Leakage Protection Type | Type B | |
| Tripping Mechanism | Residual Current | |
| Break Time | 40 ms | |
| Rated AC Voltage | 415 V ac | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 80 A | ||
Number of Poles 4 | ||
Series xEffect | ||
Range FRCmM | ||
Trip Sensitivity 300mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type B | ||
Standards/Approvals IEC/EN 61008 IEC/EN 62423 | ||
Terminal Type Twin-Purpose Terminal | ||
Height 80mm | ||
Width 70 mm | ||
Depth 76mm | ||
Breaking Capacity 800A | ||
Earth Leakage Protection Type Type B | ||
Tripping Mechanism Residual Current | ||
Break Time 40 ms | ||
Rated AC Voltage 415 V ac | ||
- COO (Country of Origin):
- DE
The Eaton residual current circuit-breaker from the Moeller xEffect series represents a pinnacle of electrical safety, ensuring protection against electrical faults while maintaining reliable performance. Engineered for both industrial and advanced commercial environments, this device is designed for seamless integration, featuring a robust build and sophisticated technology tailored to mitigate risks associated with residual current. Its four-pole configuration offers comprehensive protection for diverse applications, while the all-current sensitive design enhances safety by detecting earth faults across a wide range of conditions. The breakers compact dimensions and ease of installation make it suitable for a variety of mounting options, ensuring adaptability in different settings. With a maximum operational temperature of 75 °C, it is built to perform in demanding environments, reassuring users of its resilience and reliability.
Four-pole design ensures versatile protection for various circuit configurations
All-current sensitive technology enhances safety by detecting a broad spectrum of faults
Compact dimensions facilitate easy installation in space-constrained settings
Built to operate efficiently within a temperature range up to 75 °C
Fast tripping time ensures prompt disconnection in fault conditions
Robust construction guarantees longevity and consistent performance
Ideal for use in both industrial and advanced commercial applications
相關連結
- Eaton xEffect Series Residual Current Circuit Breaker 4-Pole Type B, 800 A 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker 4-Pole Type B, 800 A 415 V ac
- Eaton xEffect Series Residual Current Circuit Breaker 4-Pole Type B, 800 A 415 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker 4-Pole 10 kA 415 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 415 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker 4-Pole Type S/A, 10 kA 415 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker 4-Pole Type A, 800 A 210 V ac
- Eaton xEffect - FRCmM Series Residual Current Circuit Breaker 4-Pole 10 kA 415 V ac