Schneider Electric Residual Current Circuit Breaker with Overload Protection, 32 A Current Rating, 2-Pole, 30 mA Trip
- RS庫存編號:
- 654-836
- 製造零件編號:
- A9D19232
- 製造商:
- Schneider Electric
N
小計(1 件)*
TWD14,153.00
(不含稅)
TWD14,860.65
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 7 件從 2026年2月12日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD14,153.00 |
* 參考價格
- RS庫存編號:
- 654-836
- 製造零件編號:
- A9D19232
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Current Rating | 32 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Series | iC60 | |
| Range | Acti9 | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Terminal Type | Screw Clamp | |
| Depth | 72mm | |
| Width | 18 mm | |
| Height | 110mm | |
| Breaking Capacity | 10000A | |
| Application | Distribution | |
| Standards/Approvals | BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Current Rating 32 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Series iC60 | ||
Range Acti9 | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Terminal Type Screw Clamp | ||
Depth 72mm | ||
Width 18 mm | ||
Height 110mm | ||
Breaking Capacity 10000A | ||
Application Distribution | ||
Standards/Approvals BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | ||
- COO (Country of Origin):
- TH
The Schneider Electric Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P circuit breaker with 1 protected pole, 32A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life.
Neutral position is left
Number of protected poles is 1
Device location in system is outgoer
Network frequency is 50 Hz
相關連結
- Schneider Electric RCBO 2P Poles Type C, Acti9 Range
- Schneider Electric RCBO 4P Poles Type AC, Acti9 Range
- Schneider Electric RCBO 1P+N Poles Type C, Acti9 Range
- Schneider Electric RCBO 3P+N Poles Type C, Acti9 Range
- Schneider Electric RCBO 1P+N Poles Type B, Acti9 Range
- ABB RCBO 2P Poles, 30mA Trip Sensitivity
- Siemens RCBO 2P Poles SENTRON Range
- Schneider Electric RCBO 1P Poles Acti9 Range