Schneider Electric Residual Current Circuit Breaker with Overload Protection, 25 A Current Rating, 1-Pole, 100 mA Trip
- RS庫存編號:
- 654-731
- 製造零件編號:
- A9D06825
- 製造商:
- Schneider Electric
小計(1 件)*
TWD7,151.00
(不含稅)
TWD7,508.55
(含稅)
庫存資訊目前無法存取 - 請稍後再回來查看
單位 | 每單位 |
|---|---|
| 1 + | TWD7,151.00 |
* 參考價格
- RS庫存編號:
- 654-731
- 製造零件編號:
- A9D06825
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Current Rating | 25 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Number of Poles | 1 | |
| Range | Acti9 | |
| Series | iC60H | |
| Trip Sensitivity | 100mA | |
| Tripping Characteristics | Type C | |
| Terminal Type | Screw Clamp | |
| Width | 18 mm | |
| Height | 110mm | |
| Depth | 72mm | |
| Breaking Capacity | 10000A | |
| Application | Distribution | |
| Standards/Approvals | BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Current Rating 25 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Number of Poles 1 | ||
Range Acti9 | ||
Series iC60H | ||
Trip Sensitivity 100mA | ||
Tripping Characteristics Type C | ||
Terminal Type Screw Clamp | ||
Width 18 mm | ||
Height 110mm | ||
Depth 72mm | ||
Breaking Capacity 10000A | ||
Application Distribution | ||
Standards/Approvals BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | ||
- COO (Country of Origin):
- TH
The Schneider Electric Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+Ns circuit breaker with 1 protected pole, 25A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 100mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. Its unique Visitrip indicator reduces intervention time by showing the faulty circuit. Its Visisafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with IEC 61009-2-2 and IEC 61009-1 standards.
Plug on neutral cuts installation time by 50% and provides enhanced safety and reliability
Compact design is perfect for space-saving solutions
Pad lockable in ON/OFF positions
相關連結
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 3-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 1-Pole, 25000 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 1-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 4-Pole, 30 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 4-Pole, 300 mA Trip
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 2-Pole, 30 mA Trip
- Hager Residual Current Circuit Breaker with Overload Protection 4-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole