onsemi NCP12400CBAAB0DR2G 5 PWM Controller, 65 kHz 28 V 7-Pin, SOIC
- RS庫存編號:
- 178-4682
- 製造零件編號:
- NCP12400CBAAB0DR2G
- 製造商:
- onsemi
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
小計(1 包,共 10 件)*
TWD213.00
(不含稅)
TWD223.60
(含稅)
訂單超過 $1,300.00 免費送貨
最後的 RS 庫存
- 最終 850 個,準備發貨
單位 | 每單位 | 每包* |
|---|---|---|
| 10 - 620 | TWD21.30 | TWD213.00 |
| 630 - 1240 | TWD20.70 | TWD207.00 |
| 1250 + | TWD20.50 | TWD205.00 |
* 參考價格
- RS庫存編號:
- 178-4682
- 製造零件編號:
- NCP12400CBAAB0DR2G
- 製造商:
- onsemi
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | onsemi | |
| Product Type | PWM Controller | |
| Maximum Switching Frequency | 65kHz | |
| Output Voltage | 14 V | |
| Zero Power Detection | No | |
| Output Current | 500mA | |
| Number of Outputs | 5 | |
| Mount Type | Surface | |
| Minimum Supply Voltage | -0.3V | |
| Package Type | SOIC | |
| Topology | Flyback | |
| Maximum Supply Voltage | 28V | |
| Pin Count | 7 | |
| Minimum Operating Temperature | -40°C | |
| Maximum Duty Cycle | 85% | |
| PWM Controller Type | Current Mode | |
| Maximum Operating Temperature | 150°C | |
| Standards/Approvals | No | |
| Series | NCP | |
| Width | 4 mm | |
| Height | 1.5mm | |
| Length | 5mm | |
| Automotive Standard | No | |
| 選取全部 | ||
|---|---|---|
品牌 onsemi | ||
Product Type PWM Controller | ||
Maximum Switching Frequency 65kHz | ||
Output Voltage 14 V | ||
Zero Power Detection No | ||
Output Current 500mA | ||
Number of Outputs 5 | ||
Mount Type Surface | ||
Minimum Supply Voltage -0.3V | ||
Package Type SOIC | ||
Topology Flyback | ||
Maximum Supply Voltage 28V | ||
Pin Count 7 | ||
Minimum Operating Temperature -40°C | ||
Maximum Duty Cycle 85% | ||
PWM Controller Type Current Mode | ||
Maximum Operating Temperature 150°C | ||
Standards/Approvals No | ||
Series NCP | ||
Width 4 mm | ||
Height 1.5mm | ||
Length 5mm | ||
Automotive Standard No | ||
- COO (Country of Origin):
- CN
The NCP12400 is a new fixed−frequency current−mode controller featuring the Dynamic Self−Supply. This function greatly simplifies the design of the auxiliary supply and the VCC capacitor by activating the internal startup current source to supply the controller during start−up, transients, latch, stand−by etc. This device contains a special HV detector which detects the application unplug from the ac input line and triggers the X2 discharge current. This HV structure allows the brown−out detection as well. It features a timer−based fault detection that ensures the detection of overload and an adjustable compensation to help keep the maximum power independent of the input voltage.
Reduces Overall System Cost and Complexity
Ensures Skip Mode Operation Outside Audible Range
Average Efficiency Meets CoC Tier 2 Compliance
Configurable Protection Tailored for Application Needs