Eaton M22 Series White Switching Function Latching Push Button Actuator, 22.5 mm Cutout, IP66, IP67, IP69K

小計(1 件)*

TWD913.00

(不含稅)

TWD958.65

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年11月30日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD913.00

* 參考價格

RS庫存編號:
272-2219
製造零件編號:
216806 M22-DRLH-W-X0
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Series

M22

Product Type

Push Button Actuator

Cutout Diameter

22.5mm

Push Button Colour

White

Push Button Shape

Round

Push Button Actuation

Switching Function Latching

Push Button Style

Extended

Push Button Material

Plastic

IP Rating

IP66, IP67, IP69K

Push Button Marking

Labelled

Push Button Diameter

29.7mm

Standards/Approvals

IEC/EN 60947-5 VDE 0660 UL 508 UL CE UL CSA-C22.2

Hazardous Area Certification

No

豁免

COO (Country of Origin):
DE

Eaton Push Button Actuator, IP66, IP67, IP69K, White - 216806 M22-DRLH-W-X0


This push button actuator is an illuminated, maintained round control designed for panel mounting in industrial switchgear. It provides a labelled, white actuator for operator interfaces where a stay-put switching function is required and is intended for environments demanding high ingress protection.

Features and Benefits:


• IP66/IP67/IP69K rated for robust water and dust protection
• Latching switching function provides maintained state operation
• Actuating force 5N enables consistent manual operation
• Mechanical lifespan 1,000,000 operations for long service life
• Front diameter 29.7mm gives clear operator visibility

Applications


• Suitable for outdoor control panels requiring high ingress protection
• Used with machine control panels needing maintained signalling
• Can be used in maritime or offshore control enclosures
• Suitable for integration where labelled operator feedback required

What cut-out size is needed for panel installation?


The device requires a 22.5mm opening for front-panel mounting.

Which standards and approvals does it meet for industrial use?


It meets IEC/EN 60947-5 and carries UL508, CSA C22.2 and VDE 0660 approvals.

What are the operating temperature limits for field use?


The ambient operating range extends from -25°C to 70°C.

How is the bezel and front element constructed for durability?


The bezel and front element are plastic and designed to meet mechanical shock and corrosion resistance standards.

How frequently can it be cycled during normal operation?


It is rated for an operating frequency up to 1800 operations/h.