Honeywell Technologies HSCDRRN040MD2A3 Pressure SensorBoard 8 DIP
- RS庫存編號:
- 214-1454
- 製造零件編號:
- HSCDRRN040MD2A3
- 製造商:
- Honeywell
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
查看批量定價選項小計(1 盒,共 50 件)*
TWD97,205.00
(不含稅)
TWD102,065.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 250 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 | 每盒* |
|---|---|---|
| 50 - 200 | TWD1,944.10 | TWD97,205.00 |
| 250 + | TWD1,846.80 | TWD92,340.00 |
* 參考價格
- RS庫存編號:
- 214-1454
- 製造零件編號:
- HSCDRRN040MD2A3
- 製造商:
- Honeywell
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell | |
| Maximum Overload Pressure | 850mbar | |
| Sensor Type | Piezoresistive Pressure Sensor | |
| Product Type | Pressure Sensor | |
| Mount Type | Board | |
| Package Type | DIP | |
| Pin Count | 8 | |
| Minimum Supply Voltage | 3.3V | |
| Maximum Operating Pressure | 40 mbar | |
| Accuracy | ±0.25 % | |
| Maximum Supply Voltage | 5V | |
| Port Type | Dual Radial Barbed | |
| Maximum Operating Temperature | +85°C | |
| Series | HSC | |
| Standards/Approvals | ISO 9001 | |
| Width | 13.3mm | |
| Length | 10mm | |
| Height | 13.75mm | |
| Minimum Operating Pressure | -40mbar | |
| Automotive Standard | ISO 9001 | |
| Minimum Operating Temperature | -20°C | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell | ||
Maximum Overload Pressure 850mbar | ||
Sensor Type Piezoresistive Pressure Sensor | ||
Product Type Pressure Sensor | ||
Mount Type Board | ||
Package Type DIP | ||
Pin Count 8 | ||
Minimum Supply Voltage 3.3V | ||
Maximum Operating Pressure 40 mbar | ||
Accuracy ±0.25 % | ||
Maximum Supply Voltage 5V | ||
Port Type Dual Radial Barbed | ||
Maximum Operating Temperature +85°C | ||
Series HSC | ||
Standards/Approvals ISO 9001 | ||
Width 13.3mm | ||
Length 10mm | ||
Height 13.75mm | ||
Minimum Operating Pressure -40mbar | ||
Automotive Standard ISO 9001 | ||
Minimum Operating Temperature -20°C | ||
Honeywell HSC Series Differential Pressure Sensor, ±0.25% Accuracy, 3.3V Minimum Supply Voltage - HSCDRRN040MD2A3
This differential pressure sensor measures pressure difference between two ports for use with non-corrosive, non-ionic gases and selected liquids. It provides a ratiometric analogue or digital output from a single low-voltage supply and is calibrated and temperature-compensated for stable readings across typical industrial and medical operating conditions.
Features and Benefits:
• ±0.25% accuracy reduces software calibration requirements
• Operates from 3.3 to 5V for low-voltage system compatibility
• Dual radial barbed port allows straightforward tubing connections
• Compensated for 0°C to 50°C to maintain output fidelity
• Fast update rates support Rapid measurement and control loops
• Low power consumption minimises battery drain in portable systems
• Operates from 3.3 to 5V for low-voltage system compatibility
• Dual radial barbed port allows straightforward tubing connections
• Compensated for 0°C to 50°C to maintain output fidelity
• Fast update rates support Rapid measurement and control loops
• Low power consumption minimises battery drain in portable systems
Applications
• Used for airflow monitoring in respiratory equipment
• Suitable for HVAC filter clog detection and VAV control
• Ideal for gas flow instrumentation and chromatography systems
• Can be used for medical ventilator and anaesthesia monitoring
• Used with lab instruments requiring fast differential readings
• Suitable for HVAC filter clog detection and VAV control
• Ideal for gas flow instrumentation and chromatography systems
• Can be used for medical ventilator and anaesthesia monitoring
• Used with lab instruments requiring fast differential readings
What electrical Interface options are available?
It offers ratiometric analogue output and 12-14 bit digital outputs compatible with I2C or SPI communications depending on configuration.
What supply voltages are supported and how does output scale?
The device is characterised for single‑supply 3.3V or 5.0V operation and provides a ratiometric output that scales with Vsupply.
How does the sensor handle overpressure events?
It withstands significant overpressure and high burst pressures relative to its range, with overload protection values up to 850 mbar on certain differential ranges.
What diagnostic or protection options exist for fluid applications?
Liquid‑media options are available for Port1 only and diagnostic variants exist, Port2 is not compatible with liquids.
What standards and quality assurances apply to production?
The device is produced under ISO 9001 processes and incorporates on-board ASIC compensation for offset, sensitivity and non-linearity.
相關連結
- Honeywell Technologies Differential Pressure SensorThrough Hole 8 DIP
- Honeywell Technologies Differential Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies SSCDRRV015PDSA3 Differential Pressure SensorThrough Hole 8 DIP
- Honeywell Technologies ABPDRRV015PDAA5 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies ABPDRRV001PDAA5 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies ABPDRRV001PDSA3 Differential Pressure SensorThrough Hole 6 DIP
- Honeywell Technologies NSCDJJN005NDUNV Differential Pressure SensorThrough Hole 8 DIP
- Honeywell Technologies SSCDRRN005ND2A5 Differential Pressure SensorThrough Hole 8 DIP