Honeywell

Maximum Overload Pressure

2068kPa

Product Type

Pressure Sensor

Sensor Type

Piezoresistive Pressure Sensor

Mount Type

Board

Package Type

DIP

Pin Count

6

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

34.5 kPa

Accuracy

±0.25 %

Maximum Supply Voltage

5V

Port Type

Dual Radial Barbed

Maximum Operating Temperature

+85°C

Length

10mm

Standards/Approvals

ISO 9001

Width

13.3mm

Series

HSC

Height

13.75mm

Minimum Operating Pressure

-5in/H2O

Minimum Operating Temperature

-20°C

Automotive Standard

ISO 9001

COO (Country of Origin):
CN

Honeywell HSC Series Differential Pressure Sensor, ±0.25% Accuracy, 3.3V Minimum Supply Voltage - HSCDRRD005NDSA3


This differential pressure sensor measures pressure differences between two ports and provides a calibrated, temperature‑compensated output for use with non‑corrosive, non‑ionic gases in board‑mounted systems. It operates from a single 3.3V or 5.0V supply, offers ratiometric analogue or digital output, and is intended for applications requiring high stability and precision over the compensated temperature span.

Features and Benefits:


• ±0.25% accuracy reduces software compensation needs
• Operates from -20 to +85°C to cover harsh environments
• Dual radial barbed port option simplifies fluid connection
• Low power consumption under 10 mW extends battery life
• Calibrated output updated up to 2 kHz for Rapid sampling
• Available in DIP package for straightforward PCB mounting

Applications


• Suitable for medical respiratory and ventilator pressure monitoring
• Ideal for HVAC filter‑clog detection and VAV control systems
• Used with gas flow instrumentation and flow calibrators
• Can be used for barometry and indoor Air quality sensing
• Suitable for industrial pneumatic control and gas chromatography

What temperature extremes can it tolerate during operation?


It will operate across an operating temperature range of -20°C to 85°C and is characterised for compensated performance within 0°C to 50°C.

Which media are compatible with the pressure ports?


It is intended for non‑corrosive, non‑ionic gases such as air, select liquid‑media options exist for Port 1 only on higher pressure ranges.

How does the device handle overpressure and burst events?


The sensor family specifies working, overpressure and burst pressure limits per range so the module can be selected to withstand specified continuous and transient pressures.

What digital interfaces are available and what resolution do they provide?


Digital versions offer I2C or SPI‑compatible outputs with a minimum 12‑bit sensor resolution and a 14‑bit digital capability.

What manufacturing and quality standard applies to this product?


The product is designed and manufactured to ISO 9001 standards.