Festo 1/4 in G Regulator - 14 bar, MS4-LR-1/4-D6-E11-WR 1800L/min MS

小計(1 件)*

TWD5,471.00

(不含稅)

TWD5,744.55

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年4月16日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD5,471.00

* 參考價格

RS庫存編號:
342-270
製造零件編號:
MS4-LR-1/4-D6-E11-WR
製造商:
Festo
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Festo

Port Size

1/4 in G

Product Type

Regulator

Series

MS

Body Material

Die Cast Aluminium

Maximum Flow Rate

1800L/min

Maximum Operating Pressure

14 bar

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

60°C

Standards/Approvals

RoHS, VDMA24364-B1/B2-L, ISO 8573-1:2010 (7:4:4)

COO (Country of Origin):
HU

Festo MS Regulator, 1/4 inches Port Size, 14 Bar Maximum Operating Pressure - MS4-LR-1/4-D6-E11-WR, Numeric Part Number:8190238


This regulator controls pneumatic supply pressure for industrial automation tasks, providing stable outlet regulation for compressed-air systems. Designed for integration into machine and process installations, it is suited to environments where compact, serviceable pressure control is required while operating within typical industrial temperature ranges.

Features and Benefits:


• Die-cast aluminium body offers sturdy corrosion-resistant construction
• Port size 1/4in G allows standard pneumatic line connection
• Maximum flow 1800 L/min supports high-throughput systems
• Maximum operating pressure 14 bar enables robust system regulation
• Operating temperature range -10 to 60°C permits varied plant environments

Applications


• Suitable for pressure control in factory automation lines
• Ideal for feed regulation on pneumatic assembly stations
• Used for air-supply management in test rigs and benches
• Can be used for secondary pressure control on distribution manifolds

What approvals relate to fluid quality and testing standards?


It conforms to particulate and oil class criteria under ISO 8573-1:2010, specified as 7:4:4 for compressed-air quality assessment.

Which compliance marks address material and process restrictions?


The device meets RoHS restrictions and the referenced VDMA24364-B1/B2-L guideline for pneumatic component evaluation.

What environmental limits should be observed during installation?


Install within the stated -10 to 60°C range and ensure system pressure does not exceed 14 bar to maintain rated performance.

What should be considered for connecting pipework?


Use fittings compatible with 1/4in G threads and ensure manifold or tubing can handle up to 1800 L/min flow to avoid supply bottlenecks.

相關連結