Block 2 x 12 V ac 2 Output Pin PCB Transformer, EN 61558-2-6, CSA 22.2 No.66, UL 5085-1/-2, IEC 61558-2-6, DIN EN
- RS庫存編號:
- 347-2543
- 製造零件編號:
- VC 5/2/12
- 製造商:
- Block
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
小計(1 件)*
TWD549.00
(不含稅)
TWD576.45
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 47 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 11 | TWD549.00 |
| 12 - 23 | TWD538.00 |
| 24 + | TWD530.00 |
* 參考價格
- RS庫存編號:
- 347-2543
- 製造零件編號:
- VC 5/2/12
- 製造商:
- Block
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Block | |
| Secondary Voltage | 2 x 12 V ac | |
| Product Type | PCB Transformer | |
| Primary Voltage | 230 V ac | |
| Number of Outputs | 2 | |
| Length | 44mm | |
| Width | 33 mm | |
| Power | 5VA | |
| Depth | 37mm | |
| Weight | 0.19kg | |
| Mount Type | Pin | |
| Efficiency | 68% | |
| Maximum Operating Temperature | 50°C | |
| Minimum Operating Frequency | 50Hz | |
| Series | VC 5.0/2/12 | |
| Standards/Approvals | EN 61558-2-6, CSA 22.2 No.66, UL 5085-1/-2, IEC 61558-2-6, DIN EN 61558-2-6, VDE 0570 Part 2-6, ENEC (VDE), cURus | |
| Maximum Operating Frequency | 60Hz | |
| 選取全部 | ||
|---|---|---|
品牌 Block | ||
Secondary Voltage 2 x 12 V ac | ||
Product Type PCB Transformer | ||
Primary Voltage 230 V ac | ||
Number of Outputs 2 | ||
Length 44mm | ||
Width 33 mm | ||
Power 5VA | ||
Depth 37mm | ||
Weight 0.19kg | ||
Mount Type Pin | ||
Efficiency 68% | ||
Maximum Operating Temperature 50°C | ||
Minimum Operating Frequency 50Hz | ||
Series VC 5.0/2/12 | ||
Standards/Approvals EN 61558-2-6, CSA 22.2 No.66, UL 5085-1/-2, IEC 61558-2-6, DIN EN 61558-2-6, VDE 0570 Part 2-6, ENEC (VDE), cURus | ||
Maximum Operating Frequency 60Hz | ||
- COO (Country of Origin):
- DE


PCB Mount 230Vac Primary VC/VCM Series
Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)
Note
To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.
Approvals
ENEC, UL recognised
Standards
EN 61 558 IEC 61558
相關連結
- Block 12V ac 1 Output Through Hole PCB Transformer, 5VA
- Block 6V ac 2 Output Through Hole PCB Transformer, 5VA
- Block 15V ac 2 Output Through Hole PCB Transformer, 5VA
- Block 9V ac 2 Output Through Hole PCB Transformer, 5VA
- Block 18V ac 2 Output Through Hole PCB Transformer, 5VA
- Block 24V ac 2 Output Through Hole PCB Transformer, 5VA
- Block 6V ac 1 Output Through Hole PCB Transformer, 5VA
- Block 9V ac 1 Output Through Hole PCB Transformer, 5VA