Block 2 Output Pin PCB Transformer, VDE 0570 Teil 2-1, IEC 61558-2-6, IEC 61558-2-4, IEC 61558-2-1, VDE 0570 Teil 2-6,
- RS庫存編號:
- 201-7482
- 製造零件編號:
- FL 42/9
- 製造商:
- Block
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
小計(1 件)*
TWD978.00
(不含稅)
TWD1,026.90
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 9 件從 2026年1月12日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 2 | TWD978.00 |
| 3 - 5 | TWD954.00 |
| 6 + | TWD939.00 |
* 參考價格
- RS庫存編號:
- 201-7482
- 製造零件編號:
- FL 42/9
- 製造商:
- Block
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Block | |
| Product Type | PCB Transformer | |
| Primary Voltage | 2 x 115 V | |
| Number of Outputs | 2 | |
| Length | 83.5mm | |
| Width | 39 mm | |
| Depth | 70mm | |
| Weight | 0.98kg | |
| Mount Type | Pin | |
| Winding Type | Dual Secondary | |
| Isolation Voltage | 5000V | |
| Maximum Operating Temperature | 40°C | |
| Series | FL | |
| Minimum Operating Frequency | 50Hz | |
| Standards/Approvals | VDE 0570 Teil 2-1, IEC 61558-2-6, IEC 61558-2-4, IEC 61558-2-1, VDE 0570 Teil 2-6, ENEC 10 (VDE), DIN EN 61558-2-1, C-UL-US, DIN EN 61558-2-4, DIN EN 61558-2-6, UL 94 V-0, VDE 0570 Teil 2-4 | |
| Maximum Operating Frequency | 60Hz | |
| 選取全部 | ||
|---|---|---|
品牌 Block | ||
Product Type PCB Transformer | ||
Primary Voltage 2 x 115 V | ||
Number of Outputs 2 | ||
Length 83.5mm | ||
Width 39 mm | ||
Depth 70mm | ||
Weight 0.98kg | ||
Mount Type Pin | ||
Winding Type Dual Secondary | ||
Isolation Voltage 5000V | ||
Maximum Operating Temperature 40°C | ||
Series FL | ||
Minimum Operating Frequency 50Hz | ||
Standards/Approvals VDE 0570 Teil 2-1, IEC 61558-2-6, IEC 61558-2-4, IEC 61558-2-1, VDE 0570 Teil 2-6, ENEC 10 (VDE), DIN EN 61558-2-1, C-UL-US, DIN EN 61558-2-4, DIN EN 61558-2-6, UL 94 V-0, VDE 0570 Teil 2-4 | ||
Maximum Operating Frequency 60Hz | ||
- COO (Country of Origin):
- DE

PCB Mounting Low Profile 115 / 230Vac Primary
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
Twin secondary windings for series or parallel connection
Low profile compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure board mounting
Standard: EN60742, VDE 0551, IEC 61558
Note
Transformer with 2 x 24V outputs are not VDE, SEV approved.
Approvals
VDE; UL
Standards
VD 61 558
相關連結
- Block 12V ac 2 Output Through Hole PCB Transformer, 42VA
- Block 15V ac 2 Output Through Hole PCB Transformer, 42VA
- Block 18V ac 2 Output Through Hole PCB Transformer, 42VA
- Block 8V ac 2 Output Through Hole PCB Transformer, 42VA
- Block 9V ac 2 Output Through Hole PCB Transformer, 10VA
- Block 9V ac 2 Output Through Hole PCB Transformer, 52VA
- Block 9V ac 2 Output Through Hole PCB Transformer, 6VA
- Block 9V ac 2 Output Through Hole PCB Transformer, 24VA