Amprobe 34XRA Handheld Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 750V ac Max
- RS庫存編號:
- 411-683
- 製造零件編號:
- 34XR-A
- 製造商:
- Amprobe
單價(不含稅) 個
TWD9,447.00
(不含稅)
TWD9,919.35
(含稅)
5 現貨庫存,可於6工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | TWD9,447.00 |
- RS庫存編號:
- 411-683
- 製造零件編號:
- 34XR-A
- 製造商:
- Amprobe
Amprobe 34XR-A Digital Multimeter
The Amprobe 34XR-A is a True RMS digital multimeter with temperature measurement. With a Magne-Grip holster and magnetic hanging strap to keep the meter convenient, the 34XR-A is designed for contractors and field service technicians. The meter includes a Cat II 1000V, Cat III 600V safety rating.
The 34XR-A includes all the features and functions needed for a wide range of applications. The meter measures DC voltage to 1000 V, AC voltage to 750 V, AC/DC current to 10 A, resistance to 40 MΩ, capacitance to 4000 μF, frequency to 40MHz and temperature from -4 °F to 1832 °F. Additionally, the meter has a continuity beeper, diode test, overload protection, and measures duty cycle. All measurements have wide testing ranges and high accuracy. Testing results are displayed on the 3-3/4 digit LCD with 41-segment analogue bar graph.
Other features of Amprobe 34XR-A digital multimeters include an input warning tone when test leads are put in the wrong jacks; Min/Max, Data Hold and Range Lock; Auto power-off and a separate door for battery and fuse access.
The 34XR-A includes all the features and functions needed for a wide range of applications. The meter measures DC voltage to 1000 V, AC voltage to 750 V, AC/DC current to 10 A, resistance to 40 MΩ, capacitance to 4000 μF, frequency to 40MHz and temperature from -4 °F to 1832 °F. Additionally, the meter has a continuity beeper, diode test, overload protection, and measures duty cycle. All measurements have wide testing ranges and high accuracy. Testing results are displayed on the 3-3/4 digit LCD with 41-segment analogue bar graph.
Other features of Amprobe 34XR-A digital multimeters include an input warning tone when test leads are put in the wrong jacks; Min/Max, Data Hold and Range Lock; Auto power-off and a separate door for battery and fuse access.
Features and Benefits:
• DC Voltage Ranges: 400 mV, 4 V, 40 V, 400 V, 1000 V
• DC Voltage Accuracy: ±(0.5 % rdg + 1 dgt)
• AC Voltage (True RMS) Ranges: 400 mV, 4 V, 40 V, 400 V, 750 V
• AC Voltage (True RMS Accuracy: up to ±(1.2 % rdg + 8 dgts)
• AC/DC Current Ranges: 400 μA, 4 mA, 40 mA, 300 mA, 10 A
• AC/DC Current Accuracy: up to ±(1.0 % rdg + 1 dgt) DC; ±(1.5 % rdg + 8 dgts) AC
• Resistance Ranges: 400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ
• Resistance Accuracy: up to ±(1.0 % rdg + 4 dgts)
• Capacitance Ranges: 4 μF, 40 μF, 400 μF, 4000 μF
• Capacitance Accuracy: up to ±(5.0 % rdg + 5 dgts)
• Temperature Range: -4 °F to 1832 °F
• Temperature Accuracy: ± (1.0 % rdg + 6 °F )
• Frequency Ranges: 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40MHz
• Frequency Accuracy: ±(0.1 % rdg + 3 dgts)
• Continuity: Audible Indication < 35 Ω
• Duty Cycle, Diode Test, Overload Protection
• 3-3/4 digit LCD with 41-segment analog bar graph
• Cat II 1000V, Cat III 600V safety rating
• UL listed
Supplied with
• Test leads with threaded alligator clips (TL36A)
• 9 V battery
• Magne-Grip holster w/magnetic hanging strap (H2-XRA)
• Temperature adapter (TA-1)
• Type K thermocouple probe (TP255A)
• Spare fuse
• Manual
• 9 V battery
• Magne-Grip holster w/magnetic hanging strap (H2-XRA)
• Temperature adapter (TA-1)
• Type K thermocouple probe (TP255A)
• Spare fuse
• Manual
屬性 | 值 |
---|---|
Multimeter Type | Handheld |
Display Type | Digital |
Model Number p | 34XRA |
Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature |
Absolute Maximum DC Voltage Measurement | 1000V dc |
Absolute Maximum DC Current Measurement | 10A dc |
Absolute Maximum Resistance Measurement | 40MΩ |
Absolute Maximum AC Voltage Measurement | 750V ac |
Absolute Maximum AC Current Measurement | 10A ac |
Absolute Maximum Capacitance Measurement | 4mF |
Absolute Maximum Temperature Measurement | +1000°C |
Maximum Frequency | 2kHz |
DC Current Measurement Resolution | 0.1µA dc |
AC Current Measurement Resolution | 0.1µA ac |
Resistance Measurement Resolution | 100mΩ |
DC Voltage Measurement Resolution | 100µV dc |
AC Voltage Measurement Resolution | 100µV ac |
Safety Category Level | CAT II, CAT III |
Capacitance Measurement Resolution | 1nF |
Temperature Measurement Resolution | 1°C |
Best DC Voltage Accuracy | ±0.5% + 1 Digit |
Maximum Operating Temperature | +50°C |
Best AC Current Accuracy | ±2.5% + 10 Digits |
Width | 92mm |
Dimensions | 196 x 92 x 60mm |
Weight | 400g |
Height | 60mm |
Minimum Operating Temperature | 0°C |
Best Capacitance Measurement Accuracy | ±5% + 15 Digits |
Best AC Voltage Accuracy | ±2% + 8 Digits |
Best Temperature Measurement Accuracy | ±3% + 2 °C |
Safety Category Voltage | 600 V, 1000V |
Best DC Current Accuracy | ±2% + 3 Digits |
Length | 196mm |
Best Resistance Measurement Accuracy | ±2% + 5 Digits |
Battery Type | 9V |
- COO (Country of Origin):