Fluke 80AK-A Thermocouple Adapter 289 Series, 87 Series, 87V Series, 89IV Series, 902 Series, 116 Series, 1577 Series,

小計(1 件)*

TWD1,983.00

(不含稅)

TWD2,082.15

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 11 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD1,983.00

* 參考價格

RS庫存編號:
336-8292
Distrelec 貨號:
176-09-043
製造零件編號:
80AK-A
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Accessory Type

Thermocouple Adapter

Product Type

Multimeter Application Adapter

For Use With

289 Series, 87 Series, 87V Series, 89IV Series, 902 Series, 116 Series, 1577 Series, 1587 Series, 179 Series, 187 Series, 189 Series, 287 Series

Model Number

80AK-A

Standards/Approvals

No

豁免

COO (Country of Origin):
TW

Fluke Multimeter Application Adapter, Thermocouple Adaptor Type, For Use With Multiple Multimeter Series - 80AK-A


This multimeter application adaptor converts a Type-K thermocouple mini-connector to dual shrouded banana plug inputs, enabling temperature measurement with compatible handheld multimeters in low-voltage environments. It is intended for technicians and engineers working in automation, electronics, electrical and mechanical fields who need to link temperature probes to multimeters safely and conveniently.

Features & Benefits


• Adapts Type-K probe to dual banana inputs for easy connection
• Suitable for measurements when voltage is below 30VAC or below 60VDC for safety
• Probe-dependent measurement range and accuracy provide flexibility
• Compact Interface reduces setup time during field checks
• Compatible with a wide range of handheld devices for tool consolidation

Applications


• Suitable for field temperature checks with handheld digital multimeters
• Ideal for maintenance diagnostics on industrial control panels
• Used with logging or handheld meters for thermal troubleshooting
• Can be used for HVAC system temperature verification
• Used for workshop calibration tasks involving thermocouples

Which input format does it provide to the multimeter?


It presents a pair of shrouded banana plug contacts that Interface with standard dual banana meter sockets.

What limits apply when measuring near live circuits?


It is intended only for measurements where circuit potentials remain below 30VAC or 60VDC to reduce risk.

How does probe choice affect results?


The observable temperature span and reading precision depend on the specific Type-K probe characteristics used with the adaptor.

Is the adaptor suited for a range of handheld meters used in industry?


Yes, it works with many handheld devices that accept dual banana plug inputs, allowing cross-equipment compatibility.

What operational benefit does the adaptor offer technicians on-site?


It streamlines connecting temperature probes to meters, cutting setup time and simplifying inspections.