Fluke TL165X Test Lead Kit, For Use With 1650B Series, 1650 Series

小計(1 件)*

TWD9,038.00

(不含稅)

TWD9,489.90

(含稅)

Add to Basket
選擇或輸入數量
庫存資訊目前無法存取 - 請稍後再回來查看
單位
每單位
1 +TWD9,038.00

* 參考價格

RS庫存編號:
468-1063
Distrelec 貨號:
176-48-272
製造零件編號:
TL165X
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Accessory Type

Test Lead Kit

Product Type

Multi-Function Tester Accessory

For Use With

1650B Series, 1650 Series

Standards/Approvals

ANSI/ISA, EN 613261: 2006, UL, CSA

豁免

Fluke Multi-Function Tester Accessory, Black, Green and Red - TL165X


This multi-function tester accessory is a test lead kit designed to work with installation testers for use in domestic, commercial and industrial environments. It supplies detachable, slim-reach probes and fused lead connections to support a range of electrical verification tasks while allowing safe probing in confined or high-density panels.

Features & Benefits


• ANSI/ISA approved leads for recognised industry compatibility
• EN 61326-1 compliant leads for EMC performance assurance
• UL and CSA certified fused test lead kit for enhanced electrical protection
• Detachable leads permit quick replacement and field servicing
• Slim probes enable safe access to recessed terminals without obstruction
• Zero adapter support simplifies lead compensation and auto-null operation

**Applications**


• Suitable for loop impedance measurements without tripping RCDs
• Ideal for insulation resistance testing across multiple voltages
• Used with multifunction installers to measure continuity and resistance
• Can be used for RCD testing and prospective earth fault current checks
• Used for phase/wiring polarity checks on distribution panels

Are these leads compatible with other installation testers?


They are intended for use with the specified 1650-series installation testers and provide the required fused connections and detachable Interface for those instruments.

How do the leads aid insulation testing?


The set supports insulation resistance measurements by connecting to the tester’s selected test-voltage outputs and allows use of the zero adapter to subtract lead resistance from readings.

What safety behaviour is built into the leads?


Fused wiring and compatibility with live-circuit detection inhibit tests when unsafe Terminal voltages are present, reducing the risk during automated test sequences.

Can the leads be replaced in the field?


Yes, the detachable design allows straightforward replacement of worn leads without returning the main instrument for service.