Eaton SDAINL Contactor, Star Delta, 400V ac, 22 kW

小計(1 件)*

TWD25,000.00

(不含稅)

TWD26,250.00

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 1 件從 2026年6月09日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD25,000.00

* 參考價格

RS庫存編號:
535-2249
製造零件編號:
101384 SDAINLM45(400V50HZ)
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Power Rating

22kW

Product Type

Contactor

Sub Type

Star Delta

Current Rating

45A

IP Rating

IP00

Number of Poles

3

Overall Length

85mm

Maximum Voltage

400V ac

Hazardous Area Certification

NO

Standards/Approvals

IE3 Approved

Overall Width

158mm

Overall Depth

138mm

Series

SDAINL

豁免

EATON Open Chassis Star Delta Starters


Eaton's range of open chassis Star Delta starters are designed for use within customised enclosures, enabling quick and easy installation and direct mounting onto 35mm DIN rail.

Manufactured using readily available Eaton components which conform to the latest IEC 947 standards, this motor starter is pre-wired to accept the Eaton Z00 or ZB thermal overloads which offer single phasing sensitivity to IEC 947-4.

Eaton's range of Star Delta Open Chassis starters comprise of a main, delta and star contactors, Star Delta timer (adjustable between 0 and 30 seconds) and circuit diagram.

Features & Benefits:


• Suitable for motors with efficiency class IE3

• Manufacturer part numbers beginning with SDAINL00AM, 0M, 0AM, 1M, M12, M16, M22 use ZB12 overloads (typical example stock no. 493-1239)

• Manufacturer part numbers beginning with SDAINLM30, M45 and M55 use ZB32 overloads (typical example stock no. 493-1245)

• The device has an IP20 degree of protection, this means that the device is protected against solid objects up to 12 mm, for example, a person's finger. This ingress protection also means that the starter has no protection against liquidsOperating temperature range -25 to +40°C

• 7.5kW (SDAINL00AM) = H77 x W162 x D112mm

• 12.5kW & 18.5kW (SDAINL0M & SDAINL0AM) = H91 x W162 x D117mm

• 22kW (SDAINL1M) = H98 x W188 x D135mm

• 5.5 to 11kW (SDAINLM12 to SDAINLM22) = H68 x W158 x D125.2mm

• 15, 22 & 30kW (SDAINLM30 to SDAINLM55) = H85 x W158 x D147.3mm

• Overload relay is not supplied and must be ordered separately

Note: FLC figures quoted are maximum. The overload specified has been determined by applying the following formula: 0.58 x motor FLC. Allow additional clearance dimensions for the wiring bar above and below the starter.

How Does a Star Delta Starter Work?


A star delta starter is a reduced voltage motor starter and is designed to control a three-phase induction motor by reducing the starting current. Typically having a third of the inrush current compared to a DOL starter. The windings in this starter are switched between a star connection during the starting period and a delta connection once the motor reaches the required speed. A star delta power circuit will have a contactor configuration within the relay of triple pole (star) and double-throw (delta).

Note

Eaton formerly known as Moeller

相關連結