Eaton XDP DOL Starter, DOL, 400V ac, 7.5 kW, 3 Phase, IP65

此圖片僅供參考,請參閲產品詳細資訊及規格

小計(1 件)*

TWD12,667.00

(不含稅)

TWD13,300.35

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 3 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD12,667.00

* 參考價格

RS庫存編號:
528-7410
製造零件編號:
118531 XDP7,5/I(400V50HZ,440V60HZ)
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Power Rating

7.5kW

Product Type

DOL Starter

Sub Type

DOL

Number of Phases

3

Mount Type

Surface

IP Rating

IP65

Number of Poles

3

Overall Length

240mm

Maximum Voltage

400V ac

Hazardous Area Certification

NO

Standards/Approvals

No

Overall Width

160mm

Overall Depth

160mm

Series

XDP

豁免

EATON XDP DOL Starter Series with Isolator


Providing reliability and long operating life, these 'direct-on-line' starters are totally insulated with IP65 protection. Capable of high numbers of operations, these starters are constructed from standard components meaning they are very easy to maintain. Fitted with AC-3 rated triple pole contactor, AC-3 rated triple pole switch disconnector and on and off pushbuttons, these devices also allow for 3 padlocks for additional safety.

All starters in this range are wired to accept EATON overload relays for overload protection, also available from RS components to be purchased separately.

4 & 5.5kW models = H200 x W120 x D160mm, 7.5 & 11kW models = H240 x W160 x D160mm

Features and Benefits:


• Fitted with metric knockouts

• Easy maintenance

• Complies with IEE regulations

• 16th edition on isolation and switching

• Glass fibre reinforced polycarbonate casing

Applications:


Used for starting 3 phase induction motors, direct on line starters are regularly used in industrial applications such as conveyor belts, compressors and small water pumps.

What is the difference between dol and star delta starters?


Both devices are used to start induction motors however, where partial voltage is applied to each winding of a star delta starter, a DOL has 100% voltage applied. This also applies to the current, a star delta uses one-third of the starting current that a DOL does. Direct on line starters are the most common and simplest starting method, within a motor start-up they also provides the lowest temperature rise. Star delta starters allow for starting the motor at a lower voltage, making them suitable for high inertias.

Note

FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating.

Standards

IEC/EN 60529, DIN 43660, EN 50262