Dold BA9010 400V, 5.5 kW, 1 Phase Soft Starter, IP30

小計(1 件)*

TWD9,707.00

(不含稅)

TWD10,192.35

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 3 件從 2026年11月23日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD9,707.00

* 參考價格

RS庫存編號:
240-9140
製造零件編號:
BA9010 3AC230/400V 1.5/3kW
製造商:
Dold
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Dold

Product Type

Soft Starter

Power Rating

5.5kW

Number of Phases

1

IP Rating

IP30

Mount Type

DIN Rail

Maximum Supply Voltage

400V

Overall Length

121mm

Maximum Operating Temperature

60°C

Overall Width

45mm

Standards/Approvals

CE

Series

BA9010

Overall Depth

74mm

COO (Country of Origin):
DE

Soft starter, BA9010


One of the three motor phases is influenced in the BA9010 by phase control in such a way that the current in this phase rises steadily. The motor torque behaves in exactly the same way during start-up. This guarantees that the drive can start up without jerking. It is thus impossible for drive elements to be damaged, because the abrupt starting torque caused by direct starting is not generated. This property enables a cost-efficient design for the drive elements.

A marked reduction of starting noise is also perceived. Slippage or tipping over of items being conveyed on belts is avoided.

After starting, the power electronics are bridged via an internal relay contact to minimise losses in the device.

Applications


Machines with gear, belt and chain drives

Conveyor belts, fans, pumps, compressors

Packaging machines, door operating mechanisms

Inrush current limitation for single-phase transformers

Features


Increases the service life of asynchronous motors and mechanical drive components

For motor ratings up to 3 kW

Single-phase motor control

Easy installation even in existing systems

No need for a neutral conductor

Starting time and starting torque can be adjusted separately.

Can be combined with motor brake units.

Suitable for snapping onto a 35 mm standard top-hat rail

An f/V converter is frequently not needed for simple applications

Power semiconductor bridged after successful start-up

LED displays

Overall width 45 mm

Warning


If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.

相關連結

第一時間了解我們的最新產品和優惠

電郵