Dold Monitoring Relay, SPDT, DIN Rail 220 V dc
- RS庫存編號:
- 240-9049
- 製造零件編號:
- AI898 DC24V 6kOhm UH=AC45-400Hz 230V
- 製造商:
- Dold
小計(1 件)*
TWD17,073.00
(不含稅)
TWD17,926.65
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 2 件準備從其他地點送貨
- 加上 2 件從 2026年5月05日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD17,073.00 |
* 參考價格
- RS庫存編號:
- 240-9049
- 製造零件編號:
- AI898 DC24V 6kOhm UH=AC45-400Hz 230V
- 製造商:
- Dold
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Dold | |
| Product Type | Monitoring Relay | |
| Function | Monitoring | |
| Contact Configuration | SPDT | |
| Mount Type | DIN Rail | |
| Switching Voltage | 400V | |
| Power Consumption | 2.5VA | |
| IP Rating | IP40, IP20 | |
| Contact Current | 6A | |
| Supply DC Voltage | 220 V dc | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | IEC/EN 61 000-4-2, IEC/EN 61 000-4-4, UL Subject 94, IEC/EN 60 068-1, IEC/EN 61 557, IEC/EN 60 068-2-6, EN 55 011, IEC/EN 60 947-5-1, EN 50 005, IEC/EN 60 529, IEC/EN 61 000-4-5, DIN 46 228-1/-2/-3/-4, IEC 60 664-1, IEC/EN 60 715, IEC/EN 60 999-1 | |
| Height | 77mm | |
| Length | 115mm | |
| Width | 45mm | |
| Series | AI 898 | |
| 選取全部 | ||
|---|---|---|
品牌 Dold | ||
Product Type Monitoring Relay | ||
Function Monitoring | ||
Contact Configuration SPDT | ||
Mount Type DIN Rail | ||
Switching Voltage 400V | ||
Power Consumption 2.5VA | ||
IP Rating IP40, IP20 | ||
Contact Current 6A | ||
Supply DC Voltage 220 V dc | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals IEC/EN 61 000-4-2, IEC/EN 61 000-4-4, UL Subject 94, IEC/EN 60 068-1, IEC/EN 61 557, IEC/EN 60 068-2-6, EN 55 011, IEC/EN 60 947-5-1, EN 50 005, IEC/EN 60 529, IEC/EN 61 000-4-5, DIN 46 228-1/-2/-3/-4, IEC 60 664-1, IEC/EN 60 715, IEC/EN 60 999-1 | ||
Height 77mm | ||
Length 115mm | ||
Width 45mm | ||
Series AI 898 | ||
Insulation monitor for direct current networks, AI898
Fixed response time 6 kΩ
LED display for operational readiness and earth fault
1 changeover
Overall width 45 mm
The AI898 insulation monitor displays the insulation resistance of unearthed direct current networks to earth. It does not detect symmetrical earth faults. In practice, these faults are generally insignificant.
The AI898 works on the quiescent current principle, for example when the auxiliary voltage is applied to terminals A1 → A2 the output relay is activated and the "ON" LED indicates that the insulation resistance RAN is not less than the minimum value. If insulation resistance falls below the response value, the output relay drops, the "ON" LED goes out and the second LED for "Earth fault" lights up.
A bridge between terminals LT1 and LT2 (inserted as standard) allows the AI898 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. A test key (PT) tests the functional efficiency of the device (as per VDE 0435).
相關連結
- Dold Monitoring Relay DIN Rail, 230V ac
- Dold Monitoring Relay 3 Phase DIN Rail, 230V ac
- Dold Monitoring Relay SPDT 0.4mA to 10A 230V ac
- Dold Monitoring Relay DIN Rail 230V ac
- Dold Monitoring Relay DIN Rail, 600000 ipm 24 V dc
- Dold Monitoring Relay DIN Rail, 230V ac 24 V dc
- Dold Monitoring Relay 2V ac 220 V ac
- Dold Monitoring Relay DIN Rail 12 V dc, 230V ac