Dold Monitoring Relay, 3 Phase, 0.8 to 1.1 UN Monitor Range, DPDT, DIN Rail
- RS庫存編號:
- 240-8923
- 製造零件編號:
- BA9041 3AC50Hz 400V
- 製造商:
- Dold
小計(1 件)*
TWD5,508.00
(不含稅)
TWD5,783.40
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 14 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD5,508.00 |
* 參考價格
- RS庫存編號:
- 240-8923
- 製造零件編號:
- BA9041 3AC50Hz 400V
- 製造商:
- Dold
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Dold | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 3 | |
| Contact Configuration | DPDT | |
| Mount Type | DIN Rail | |
| Power Consumption | 3.5VA | |
| Switching Voltage | 230V ac | |
| IP Rating | IP20, IP40 | |
| Contact Current | 5A | |
| Monitoring Voltage Range | 0.8 to 1.1 UN | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Width | 45mm | |
| Series | BA 9041 | |
| Height | 73.2mm | |
| Length | 119.8mm | |
| Standards/Approvals | IEC/EN 60 715, IEC/EN 60 255-1, IEC/EN 61 000-4-4, IEC/EN 61 000-4-2, IEC/EN 60 999-1, EN 50 005, UL Subject 94, IEC/EN 61 000-4-5, EN 55 011, IEC/EN 60 068-1, IEC/EN 61 000-4-6, IEC/EN 61 000-4-3, IEC/EN 60 947-5-1, DIN 46 228-1/-2/-3/-4, IEC/EN 60 068-2-6 | |
| 選取全部 | ||
|---|---|---|
品牌 Dold | ||
Product Type Monitoring Relay | ||
Electrical Phase 3 | ||
Contact Configuration DPDT | ||
Mount Type DIN Rail | ||
Power Consumption 3.5VA | ||
Switching Voltage 230V ac | ||
IP Rating IP20, IP40 | ||
Contact Current 5A | ||
Monitoring Voltage Range 0.8 to 1.1 UN | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Width 45mm | ||
Series BA 9041 | ||
Height 73.2mm | ||
Length 119.8mm | ||
Standards/Approvals IEC/EN 60 715, IEC/EN 60 255-1, IEC/EN 61 000-4-4, IEC/EN 61 000-4-2, IEC/EN 60 999-1, EN 50 005, UL Subject 94, IEC/EN 61 000-4-5, EN 55 011, IEC/EN 60 068-1, IEC/EN 61 000-4-6, IEC/EN 61 000-4-3, IEC/EN 60 947-5-1, DIN 46 228-1/-2/-3/-4, IEC/EN 60 068-2-6 | ||

Phase sequence relay, BA9041
Detects phase sequence errors and phase failure
with 2 changeovers
Overall width 45 mm
The BA9041 can recognise the phase sequence L1 - L2 - L3 of a three-phase network and therefore avoid an incorrect rotational direction.
The BA9041 phase sequence relay monitors the presence of the 3 phase voltages in a three-phase network in addition to the maintenance of the correct phase sequence. If all 3 phase voltages are present at the device in the correct phase sequence, the output contacts change over from the initial position to the operative position, contacts 11-14 and 21-24 are closed, and a green LED lights up.
If the voltage falls below 60 % UN in one phase, the relay is de-energised (in accordance with: IEC 255, VDE 0435).
Phase Sequence/Failure Relays
Monitoring of 3 phase supplies
Orange housing manufactured to DIN 43 880
DIN rail mount
相關連結
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range DIN Rail, 400V ac
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range 400V ac
- Dold Monitoring Relay 0.7 to 1.1 UN Monitor Range DIN Rail
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range 230V ac, 400 V ac
- Dold Monitoring Relay 0.7 to 1.3 UN Monitor Range DIN Rail 80 to 230 V dc
- Dold Monitoring Relay DIN Rail
- Dold Monitoring Relay 1 Phase DPDT, DIN Rail 110 to 240 V dc
- Dold Monitoring Relay DPDT, DIN Rail