Tele Monitoring Relay, 3 Phase, 230/400 V ac Monitor Range, DPDT, DIN Rail, 250V ac
- RS庫存編號:
- 182-9992
- Distrelec 貨號:
- 137-54-202
- 製造零件編號:
- E3YF400V02 0.85
- 製造商:
- Tele
小計(1 件)*
TWD4,394.00
(不含稅)
TWD4,613.70
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 14 件從 2026年8月06日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD4,394.00 |
* 參考價格
- RS庫存編號:
- 182-9992
- Distrelec 貨號:
- 137-54-202
- 製造零件編號:
- E3YF400V02 0.85
- 製造商:
- Tele
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Tele | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 3 | |
| Function | Overvoltage | |
| Contact Configuration | DPDT | |
| Mount Type | DIN Rail | |
| Power Consumption | 11VA | |
| Terminal Type | Shockproof | |
| IP Rating | IP20, IP40 | |
| Supply AC Voltage | 250V ac | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -25°C | |
| Monitoring Voltage Range | 230/400 V ac | |
| Maximum Operating Temperature | 55°C | |
| Length | 65mm | |
| Standards/Approvals | RoHS | |
| Width | 35mm | |
| Series | ENYA | |
| Height | 87mm | |
| 選取全部 | ||
|---|---|---|
品牌 Tele | ||
Product Type Monitoring Relay | ||
Electrical Phase 3 | ||
Function Overvoltage | ||
Contact Configuration DPDT | ||
Mount Type DIN Rail | ||
Power Consumption 11VA | ||
Terminal Type Shockproof | ||
IP Rating IP20, IP40 | ||
Supply AC Voltage 250V ac | ||
Contact Current 5A | ||
Minimum Operating Temperature -25°C | ||
Monitoring Voltage Range 230/400 V ac | ||
Maximum Operating Temperature 55°C | ||
Length 65mm | ||
Standards/Approvals RoHS | ||
Width 35mm | ||
Series ENYA | ||
Height 87mm | ||
- COO (Country of Origin):
- AT
Voltage monitoring 3-phase against N, Voltage failure monitoring, 400V, 2 CO, fixed threshold voltage Us=195,5V
Monitoring relays - ENYA series
Undervoltage monitoring
Supply voltage = measured voltage
2 change over contacts
Width 35 mm
Installation design
Task
The emergency lighting is activated in the event of a mains failure or undervoltage.
Solution
The mains failure is monitored with a E3YF400V02 (three phases). If the voltage falls below 85% of the nominal voltage, the output relay trips and turns the emergency lights on.
Use/value
Detects mains failure
Applications
Emergency Power
Facility Management
Renewable Energy
相關連結
- Tele Monitoring Relay SPDT 400V ac
- Tele Monitoring Relay 400 V ac Monitor Range DIN Rail, 400V ac
- Tele Monitoring Relay 24/230 V ac Monitor Range DIN Rail, 230V ac
- Tele Monitoring Relay 177/794 V ac Monitor Range DIN Rail 690 V ac
- Tele Monitoring Relay 160 to 240 V Monitor Range DIN Rail 400 V ac
- Tele Phase/Voltage Monitoring Relays 400 V ac Monitor Range 110V ac, 230 V ac 24 V dc
- Hiquel Monitoring Relay 80/260 V Monitor Range DIN Rail 230 V ac
- Tele Monitoring Relay DIN Rail, 400V ac
