Dold Insulation Monitoring Relay, 1, 3 Phase, DPDT, 0 → 500V ac, DIN Rail
- RS庫存編號:
- 181-2773
- 製造零件編號:
- MK5880N.12 DC24V 5-100kOhm
- 製造商:
- Dold
小計(1 件)*
TWD8,128.00
(不含稅)
TWD8,534.40
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年1月14日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD8,128.00 |
* 參考價格
- RS庫存編號:
- 181-2773
- 製造零件編號:
- MK5880N.12 DC24V 5-100kOhm
- 製造商:
- Dold
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Dold | |
| Monitoring Application | Insulation | |
| Electrical Phase | 1, 3 | |
| Voltage Sensing Range | 0 → 500V ac | |
| Contact Configuration | DPDT | |
| Mounting Type | DIN Rail | |
| Series | MK5880N | |
| Minimum Operating Temperature | -20°C | |
| Operating Temperature Range | +60°C | |
| Dimensions | 97 x 22.5 x 90mm | |
| Minimum Voltage Sensed | 0V ac | |
| Length | 97mm | |
| Maximum Operating Temperature | +60°C | |
| Width | 22.5mm | |
| Height | 90mm | |
| Terminal Type | Screw | |
| Maximum Voltage Sensed | 500V ac | |
| 選取全部 | ||
|---|---|---|
品牌 Dold | ||
Monitoring Application Insulation | ||
Electrical Phase 1, 3 | ||
Voltage Sensing Range 0 → 500V ac | ||
Contact Configuration DPDT | ||
Mounting Type DIN Rail | ||
Series MK5880N | ||
Minimum Operating Temperature -20°C | ||
Operating Temperature Range +60°C | ||
Dimensions 97 x 22.5 x 90mm | ||
Minimum Voltage Sensed 0V ac | ||
Length 97mm | ||
Maximum Operating Temperature +60°C | ||
Width 22.5mm | ||
Height 90mm | ||
Terminal Type Screw | ||
Maximum Voltage Sensed 500V ac | ||
- COO (Country of Origin):
- DE
For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
Monitors also disconnected voltage systems
Adjustable tripping value RALof 5 ... 100 kΩ
De-energized on trip
Auxiliary voltage, measuring circuit and output contacts are galvanically separated
Manual and auto reset
With test and reset button
Connections for external test and reset buttons possible
LED indicators for operation and alarm
2 changeover contacts
MK 5880N/200 with additional pre warning
adjustable pre warning value 10 kΩ ... 5 MΩ
1 output relay for alarm and 1 for pre-warning
MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
As option with pluggable terminal blocks for easy exchange of devices
with screw terminals
or with cage clamp terminals
Monitors also disconnected voltage systems
Adjustable tripping value RALof 5 ... 100 kΩ
De-energized on trip
Auxiliary voltage, measuring circuit and output contacts are galvanically separated
Manual and auto reset
With test and reset button
Connections for external test and reset buttons possible
LED indicators for operation and alarm
2 changeover contacts
MK 5880N/200 with additional pre warning
adjustable pre warning value 10 kΩ ... 5 MΩ
1 output relay for alarm and 1 for pre-warning
MH 5880/500: similar to MK 5880N but with galvanic separated analogue output and 11 step LED chain for the actual insulation value
Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
As option with pluggable terminal blocks for easy exchange of devices
with screw terminals
or with cage clamp terminals