Schneider Electric Monitoring Relay, 1 Phase, DPDT, DIN Rail, 150mA to 15A, 24V ac, 240 V ac
- RS庫存編號:
- 124-0191
- Distrelec 貨號:
- 301-12-082
- 製造零件編號:
- RM35JA32MR
- 製造商:
- Schneider Electric
小計(1 件)*
TWD5,731.00
(不含稅)
TWD6,017.55
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 8 件從 2026年6月01日 起發貨
- 加上 3 件從 2026年6月05日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD5,731.00 |
* 參考價格
- RS庫存編號:
- 124-0191
- Distrelec 貨號:
- 301-12-082
- 製造零件編號:
- RM35JA32MR
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 1 | |
| Contact Configuration | DPDT | |
| Mount Type | DIN Rail | |
| Minimum Current Sensed | 150mA | |
| Switching Voltage | 250V ac | |
| Power Consumption | 3.5VA | |
| Maximum Current Sensed | 15A | |
| Current Sensitivity | Overcurrent, Undercurrent | |
| Terminal Type | Screw | |
| IP Rating | IP20, IP30, IP50 | |
| Time Delay | 0.1 to 30 s | |
| Minimum Operating Temperature | -20°C | |
| Supply AC Voltage | 24, 240V ac | |
| Relay Contact Current | 8A | |
| Maximum Operating Temperature | 60°C | |
| Series | Harmony Control | |
| Width | 35mm | |
| Standards/Approvals | RoHS, IEC 60068-2-30, IEC 60255-27, IEC 60068-2-6, REACH, IEC 60068-2-27 | |
| Length | 72.05mm | |
| Height | 90mm | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Product Type Monitoring Relay | ||
Electrical Phase 1 | ||
Contact Configuration DPDT | ||
Mount Type DIN Rail | ||
Minimum Current Sensed 150mA | ||
Switching Voltage 250V ac | ||
Power Consumption 3.5VA | ||
Maximum Current Sensed 15A | ||
Current Sensitivity Overcurrent, Undercurrent | ||
Terminal Type Screw | ||
IP Rating IP20, IP30, IP50 | ||
Time Delay 0.1 to 30 s | ||
Minimum Operating Temperature -20°C | ||
Supply AC Voltage 24, 240V ac | ||
Relay Contact Current 8A | ||
Maximum Operating Temperature 60°C | ||
Series Harmony Control | ||
Width 35mm | ||
Standards/Approvals RoHS, IEC 60068-2-30, IEC 60255-27, IEC 60068-2-6, REACH, IEC 60068-2-27 | ||
Length 72.05mm | ||
Height 90mm | ||
Schneider Electric Harmony Control Series Monitoring Relay, 24/240V AC Supply Voltage, 0.1 to 30 s Time Delay - RM35JA32MR
This monitoring relay provides single-phase current supervision for overcurrent and undercurrent conditions in industrial control panels. Designed for DIN-rail mounting, it monitors AC/DC currents and issues changeover contact outputs for protection or control logic. The unit accepts a wide supply range and is suited to panel installations requiring adjustable trip timing.
Features & Benefits
• 0.15 to 15A measurement range for broad current detection capability
• Adjustable 0.1 to 30s time delay for controlled response timing
• 2C/O contacts delivering 8A switching for load interfacing
• 24 to 240V AC/DC supply with 20.4 to 264V tolerance for flexible powering
• 3.5VA power consumption minimises panel load and heating
• LED indicators for power and relay state to aid diagnostics
• Adjustable 0.1 to 30s time delay for controlled response timing
• 2C/O contacts delivering 8A switching for load interfacing
• 24 to 240V AC/DC supply with 20.4 to 264V tolerance for flexible powering
• 3.5VA power consumption minimises panel load and heating
• LED indicators for power and relay state to aid diagnostics
Applications
• Suitable for motor protection trips using overcurrent detection
• Ideal for monitoring pump circuits for undercurrent faults
• used with control panels requiring adjustable delay tripping
• Suitable for factory automation where DIN-rail mounting is required
• Used for supervisory signalling to PLCs or control systems
• Ideal for monitoring pump circuits for undercurrent faults
• used with control panels requiring adjustable delay tripping
• Suitable for factory automation where DIN-rail mounting is required
• Used for supervisory signalling to PLCs or control systems
What connection types are provided for wiring?
Screw terminals accept 0.5 to 3.3mm2 conductors depending on single or double wiring and facilitate crimped or solid terminations with 0.6 to 1N·m tightening torque.
How does the relay perform under varying supply voltages?
Threshold and timing maintain stability within supply limits
setting accuracy is ±10% of full scale and drift is ≤1% across the supply range.
What environmental conditions can it withstand in operation?
Operational temperature spans -20 to 60°C depending on line frequency, with high humidity tolerance and resistance to industrial-level EMC disturbances.
How Durable are the switching elements?
Contacts are cadmium-free with electrical durability rated to 100,000 cycles and mechanical endurance to 10,000,000 cycles.
相關連結
- Schneider Electric Monitoring Relay DPDT 150mA to 15A 415 V ac
- Dold Monitoring Relay DPDT 0.1A to 15A 240 V ac
- Schneider Electric Monitoring Relay DPDT 0.15A to 15A 240V ac
- ABB Monitoring Relay DPDT 0.3A to 15A 240V ac
- Tele Monitoring Relay DPDT 24V ac, 240 V ac
- Schneider Electric Monitoring Relay DPDT 24V ac, 240 V ac 24 to 240 V ac
- Schneider Electric Monitoring Relay DPDT 24V ac, 240 V ac
- Schneider Electric Monitoring Relay DPDT 110V ac, 240 V ac