Monitoring Voltage Range

20 V ac→600 V ac

Minimum Operating Temperature

-20°C

Contact Current

10A

Supply DC Voltage

20.4→26.4 V

Maximum Operating Temperature

60°C

Height

90mm

Length

90mm

Standards/Approvals

EN 60947-5-1, RoHS, UL 60947-5-1

Width

17.5mm

Series

K8DT-VS

COO (Country of Origin):
CN

Omron K8DT-VS Series Monitoring Relay, 20 to 600VAC Monitoring Voltage Range, 10A Contact Current - K8DT-VS3CD


This monitoring relay provides voltage supervision for single‑phase systems and is designed for mounting on a DIN rail in industrial control panels. It monitors alternating voltage within a broad range and switches a single changeover contact to signal abnormal conditions, making it suitable for protection and monitoring tasks in automation and electrical installations.

Features and Benefits:


• Monitors 20 to 600VAC for wide‑range voltage detection • Single‑pole changeover contact rated at 10A for load control • Accepts AC and DC supply of 20.4-26.4V for flexible powering • Push‑in terminals for rapid, secure field wiring • Low power consumption of 1.8VA to reduce panel energy draw • Complies with relevant safety standards for industrial use

Applications


• Suitable for control‑panel voltage supervision in factories • Ideal for motor protection circuits requiring voltage monitoring • Used with PLC inputs to provide fault signalling in automation • Can be used for distribution‑board undervoltage detection • Used for maintenance systems that require Compact DIN‑rail devices

What environmental limits apply to its operation?


It operates between -20°C and 60°C, allowing use across typical indoor industrial temperature ranges.

How does it integrate into Compact panels?


The unit has a slim width of 17.5mm and mounts on standard DIN rail to save panel space.

What ingress protection does the enclosure provide?


The housing is rated IP20, offering protection against contact with internal parts but not against liquids.

What standards govern its safety and performance?


It meets EN 60947-5-1 and UL 60947-5-1 requirements and conforms to RoHS restrictions.