Schneider Electric Monitoring Relay, 1 Phase, SPDT, DIN Rail, 240V ac 240 V dc

小計(1 件)*

TWD5,465.00

(不含稅)

TWD5,738.25

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 12 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD5,465.00

* 參考價格

RS庫存編號:
146-171
製造零件編號:
RM17UAS15
製造商:
Schneider Electric
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Schneider Electric

Product Type

Monitoring Relay

Electrical Phase

1

Function

Undervoltage Monitoring, Overvoltage

Contact Configuration

SPDT

Mount Type

DIN Rail

Switching Voltage

250V ac/dc

Power Consumption

3VA

Terminal Type

Screw

IP Rating

IP30, IP20

Supply AC Voltage

240V ac

Minimum Operating Temperature

-20°C

Contact Current

5A

Supply DC Voltage

240 V dc

Maximum Operating Temperature

50°C

Standards/Approvals

CSA, UL, NF EN 60255-6 and IEC 60255-6, GL, C-Tick, GOST

Length

72mm

Series

Harmony Control

Height

90mm

Width

17.5mm

COO (Country of Origin):
ID

Schneider Electric Harmony Control Series Monitoring Relay, SPDT Contact Configuration, Voltage Monitoring Application - RM17UAS15


This monitoring relay is specifically developed for voltage control applications. Its detection features ensure that electrical systems function within safe voltage boundaries, protecting sensitive equipment against potential damage caused by voltage fluctuations.

Features & Benefits


• Voltage sensing range of 65 to 260V AC/DC

• Adjustable time delay from 0.1 to 10 seconds

• Incorporates overvoltage and undervoltage detection

• Designed for straightforward installation on DIN rail

• Features screw terminal connections for secure wiring

• Supports multiple electrical phases for varied applications

Applications


• Monitoring voltage in electrical control panels

• Utilised in industrial voltage monitoring systems

• Applied in automation processes requiring accurate voltage regulation

• Protecting machinery from voltage variations

• Suitable for single-phase and DC supply scenarios

Can it be adjusted for different voltage sensitivity ranges?


Yes, the sensitivity settings can be configured to detect specific voltage thresholds according to system requirements.

What steps are involved in installing it onto a DIN rail?


Align the relay with the rail and push it down until it clicks securely.

How does it handle power interruptions?


The relay maintains functionality during brief voltage interruptions, offering immunity to microbreaks.

Is it suitable for various electrical environments?


Yes, it operates efficiently in both industrial and residential settings.

What maintenance is required for optimal performance?


Regular visual inspections and ensuring connections remain secure are advisable to maintain reliability.

Approvals

UL, CSA, GL, C-Tick, GOST

Standards

NF EN 60255-6 and IEC 60255-6