Eaton, NZM, NZM Molded Case Circuit Breaker 3-Pole 125 A, Breaking Capacity 18.5 kA, Plug-in
- RS庫存編號:
- 229-536
- 製造零件編號:
- 113196 NZMB2-M125-SVE
- 製造商:
- Eaton
小計(1 件)*
TWD33,487.00
(不含稅)
TWD35,161.35
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年3月02日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD33,487.00 |
* 參考價格
- RS庫存編號:
- 229-536
- 製造零件編號:
- 113196 NZMB2-M125-SVE
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Range | NZM | |
| Product Type | Molded Case Circuit Breaker | |
| Series | NZM | |
| Number of Poles | 3 | |
| Current Rating | 125 A | |
| Breaking Capacity | 18.5kA | |
| Rated AC Voltage | 440 V ac | |
| Mount Type | Plug-in | |
| Terminal Type | Screw | |
| Standards/Approvals | RoHS, IEC/EN 60947 | |
| Height | 245mm | |
| Depth | 180mm | |
| Width | 105 mm | |
| Break Time | 10 ms | |
| Tripping Characteristics | Thermomagnetic | |
| Reset Actuator Type | Rocker Lever | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Range NZM | ||
Product Type Molded Case Circuit Breaker | ||
Series NZM | ||
Number of Poles 3 | ||
Current Rating 125 A | ||
Breaking Capacity 18.5kA | ||
Rated AC Voltage 440 V ac | ||
Mount Type Plug-in | ||
Terminal Type Screw | ||
Standards/Approvals RoHS, IEC/EN 60947 | ||
Height 245mm | ||
Depth 180mm | ||
Width 105 mm | ||
Break Time 10 ms | ||
Tripping Characteristics Thermomagnetic | ||
Reset Actuator Type Rocker Lever | ||
豁免
- COO (Country of Origin):
- RO
The Eaton NZM series thermal-magnetic circuit breaker represents a sophisticated choice for modern electrical installations. Designed for robust performance, this model offers superior protection for electric circuits against overloads and short-circuits. With its three-pole configuration and a substantial current rating of 125 A, it meets the demanding needs of a wide range of applications. The circuit breaker is engineered for easy integration into unearthed supply systems at voltages up to 440 V. Additionally, it boasts a compact design which facilitates efficient installation, making it a preferred choice among panel builders and electrical engineers alike. The NZM series is recognised for its combinative features of thermomagnetic release, high breaking capacity, and ease of use, ensuring both reliability and safety in power distribution.
Robust design ensures optimal reliability in electrical distribution
Thermo-magnetic technology provides precise overload and short-circuit protection
Compact dimensions enhance ease of installation even in tight spaces
Superior breaking capacity for effective handling of high short-circuit currents
Rated for use in harsh environments, maintaining performance at extreme temperatures
Flexibility in application across various electrical systems, including industrial settings
User-friendly operation with a clear, rocker lever handle for instant access
相關連結
- Eaton Breaking Capacity 18.5 kA, Fixed Mount
- Eaton Breaking Capacity 18.5 kA, Plug In
- Eaton Breaking Capacity 25 kA, Fixed Mount
- Eaton Moeller NZM MCCB Molded Case Circuit Breaker 3P 125A Fixed Mount
- Eaton Breaking Capacity 5 kA, Plug In
- Eaton Breaking Capacity 4 kA, Plug In
- Eaton Breaking Capacity 18.5 kA, Plug In
- Eaton Breaking Capacity 18.5 kA, Plug In