Eaton xEffect MCB, 1P, 6A Curve D, 240V AC, 48V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 922-7033
- 製造零件編號:
- 278578 FAZ-D6/1
- 製造商:
- Eaton
小計(1 件)*
TWD1,063.00
(不含稅)
TWD1,116.15
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 253 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD1,063.00 |
* 參考價格
- RS庫存編號:
- 922-7033
- 製造零件編號:
- 278578 FAZ-D6/1
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Number of Poles | 1 | |
| Current Rating | 6A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 240V | |
| Rated DC Voltage | 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Length | 17.8mm | |
| Width | 66mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 80mm | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal-Magnetic | |
| Break Time | Instantaneous | |
| Terminal Contact Type | Screw | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Number of Poles 1 | ||
Current Rating 6A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 240V | ||
Rated DC Voltage 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Length 17.8mm | ||
Width 66mm | ||
Mounting Style DIN Rail Mount | ||
Depth 80mm | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal-Magnetic | ||
Break Time Instantaneous | ||
Terminal Contact Type Screw | ||
Eaton MCB, IP20 Rating, 17.5mm Mounting Width - FAZ Series - 278578 FAZ-D6/1
Stop wayward currents in their tracks with this single-pole MCB from Eaton. It's an electrical safety device that protects equipment and people against overcurrents by automatically disconnecting power supplies when faults occur. The unit's rapid short-circuit response minimises rogue loads to reduce downtime. A trip-free mechanism means impatient fingers can't forcibly hold the breaker in the ON position – it can only be reset when the fault is cleared. Simply clip the unit onto a DIN rail for quick and tool-free mounting. It's commonly used to support kit such as medical machinery and UPS systems.
Features & Benefits
• Thermal-magnetic tripping mechanism for combined protection against overloads and short circuits
• Front switch toggle for easy resets and a clear indication of contact position
• IEC/EN 60898 compliance shows the device is approved in Europe for quality and safety
• Front switch toggle for easy resets and a clear indication of contact position
• IEC/EN 60898 compliance shows the device is approved in Europe for quality and safety
How big is this MCB?
With a mounting width of just 17.5mm, you can squeeze this MCB onto busy rails and save space on panels.
What's a type-D tripping curve?
A D-curve device like this one is suitable for very high inductive loads as it trips when it receives between 10 and 20 times the rated current. In this instance, that's 6A.
Note
Eaton formerly known as Moeller
相關連結
- Eaton xEffect MCB 6A Curve B 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 6A Curve D 60V DC, 15 kA Breaking Capacity
- Eaton xEffect MCB 6A Curve D 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 6A Curve K 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 1A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 6A Curve B 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 6A Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 6A Curve D 60V DC, 15 kA Breaking Capacity