Eaton xEffect FAZ MCB, 3P, 63A Curve D, 240 → 415V AC, 96V DC, 10 kA Breaking Capacity

小計(1 件)*

TWD4,957.00

(不含稅)

TWD5,204.85

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 7 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD4,957.00

* 參考價格

RS庫存編號:
922-6933
製造零件編號:
115375 FAZ-D63/3
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Number of Poles

3

Current Rating

63A

Tripping Characteristics

Type D

Rated AC Voltage

240 → 415V

Rated DC Voltage

96V

Breaking Capacity at Maximum Voltage Rating

10 kA

Range

xEffect

Series

FAZ

Circuit Breaker Type

MCB

Width

54mm

Length

80mm

Mounting Style

DIN Rail Mount

Depth

80mm

Application

Commercial, Industrial

Reset Actuator Type

Toggle Switch

Tripping Mechanism

Thermal-Magnetic

Break Time

Instantaneous

Terminal Contact Type

Screw

Eaton FAZ Series MCB, 63A Current Rating, Type D Tripping Characteristics - 115375 FAZ-D63/3


This miniature circuit breaker falls under the FAZ series and is ideal for commercial and industrial applications. Designed with three poles and a current rating of 63A, it provides reliable circuit protection. With dimensions of 54mm in width and 80mm in both length and depth, it is suitable for DIN rail mounting, ensuring straightforward installation.

Features & Benefits


• Offers a high breaking capacity of 10kA for enhanced safety

• Combines thermal and magnetic mechanisms for reliable operation

• Operational voltage range from 240 to 415 V for versatile usage

• Provides instantaneous break time, ensuring swift fault response

Applications


• Used in commercial settings for reliable electrical distribution

• Utilised in industrial circuits requiring robust protection

• Suitable for advanced switchgear

What benefits does the thermal-magnetic mechanism provide?


The thermal-magnetic mechanism ensures quick response to overloads and short circuits, increasing circuit safety and reliability in various electrical systems.

How does the high breaking capacity enhance safety in applications?


The high breaking capacity allows the circuit breaker to handle fault currents effectively, preventing damage to electrical components and reducing fire hazards.

What are the implications of the Type D tripping characteristic?


Type D trip characteristics are particularly advantageous for circuits with high inrush currents, making them ideal for motors and transformers, ensuring consistent operation without unnecessary trips.

What installation considerations should be taken into account?


It's important to ensure adequate space on the DIN rail for proper mounting and to verify that all connections conform to appropriate electrical standards for stability and safety.

What temperature range can this circuit breaker operate in?


It operates effectively within a temperature range of -40°C to 70°C, accommodating various environmental conditions typically found in commercial and industrial settings.

Note

Eaton formerly known as Moeller

相關連結